Solar Calculator Canada

Solar Power Calculator for Bruce Mines, Ontario, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Bruce Mines
  • GPS Coordinates: 46.301, -83.79467
  • Elevation: 177 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Bruce Mines: 37o
  • Average yearly irradiance: 1512.8 kWh/m2
  • Average yearly power output: 129239 kWh
Sun Path Bruce Mines

Average yearly irradiance delivered by the Sun in Bruce Mines is 1512.8/kWh/m2 at the optimal panel slope of 37o. After taking all losses into account, you can expect about 129239 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 37o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.99 61.74
February 3.1 86.74
March 4.58 141.89
April 5.23 156.92
May 5.7 176.68
June 5.77 173.03
July 5.97 185
August 5.49 170.31
September 4.65 139.35
October 3.34 103.48
November 2.14 64.3
December 1.72 53.33
Total yearly 1512.8

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 186.29 5775.02
February 291.24 8154.64
March 416.07 12898.1
April 459.1 13773
May 483.5 14988.5
June 469.7 14090.9
July 480.22 14886.7
August 443.77 13757
September 383.74 11512.2
October 286.44 8879.54
November 189.01 5670.37
December 156.56 4853.33
Total yearly 129239

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Bruce Mines solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 138.29 4286.89
February 234.44 6564.22
March 367.94 11406
April 447.02 13410.7
May 503.03 15593.9
June 503.83 15114.9
July 508.84 15774
August 444.74 13786.9
September 353.46 10603.9
October 240.32 7449.8
November 144.55 4336.58
December 111.74 3463.95
Total yearly 121792

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 151.17 4686.31
February 250.3 7008.31
March 382.94 11871
April 454.29 13628.6
May 502.65 15582.1
June 499.82 14994.7
July 506.47 15700.6
August 448.69 13909.4
September 364 10920
October 253.58 7860.87
November 156.6 4698.08
December 123.6 3831.67
Total yearly 124692

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 162.81 5047.25
February 264.35 7401.88
March 395.52 12261.2
April 458.98 13769.3
May 500.14 15504.4
June 493.62 14808.7
July 501.98 15561.3
August 450.24 13957.4
September 372.38 11171.3
October 265.16 8219.87
November 167.46 5023.89
December 134.41 4166.67
Total yearly 126893

Bruce Mines Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 173.19 5368.77
February 276.57 7743.89
March 405.66 12575.4
April 461.04 13831.1
May 495.63 15364.5
June 485.66 14569.7
July 494.77 15337.7
August 449.43 13932.3
September 378.55 11356.6
October 275.02 8525.48
November 177.09 5312.81
December 144.12 4467.72
Total yearly 128386

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.88% angle of incidence loss and -2.26% temperature and irradiance loss. This totals to about -14.57%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

CormackGodboutPoint LeamingtonBirchy BayQualicum BeachMorrisCarmanvilleLampmanWillow BunchBengoughMidaleGibsonsSouth BrookMagrathRadvilleRaymondTrout RiverRobert's ArmHartneyLeading TicklesSummerfordNorris PointHampdenRedversOgemaMurdochville