Solar Calculator Canada

Solar Power Calculator for Radville, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Radville
  • GPS Coordinates: 49.4609861, -104.2973611
  • Elevation: 636 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Radville: 42o
  • Average yearly irradiance: 1623.13 kWh/m2
  • Average yearly power output: 137796 kWh
Sun Path Radville

Average yearly irradiance delivered by the Sun in Radville is 1623.13/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 137796 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.33 72.19
February 2.94 82.24
March 4.01 124.16
April 5.58 167.29
May 5.83 180.79
June 5.98 179.53
July 6.66 206.47
August 6.1 189.1
September 5.38 161.41
October 3.93 121.82
November 2.67 80.06
December 1.87 58.06
Total yearly 1623.13

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 221.42 6863.98
February 274.94 7698.29
March 357.57 11084.7
April 480.17 14405.2
May 485.95 15064.5
June 485.76 14572.9
July 531.24 16468.4
August 488.36 15139.2
September 443.71 13311.4
October 339.14 10513.2
November 240.97 7229.06
December 175.64 5444.79
Total yearly 137796

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Radville solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 142 4402.1
February 202.17 5660.7
March 305.47 9469.66
April 459.97 13799.2
May 510.41 15822.8
June 529.83 15894.9
July 566.33 17556.2
August 483.89 15000.7
September 392.65 11779.6
October 263.88 8180.29
November 164.49 4934.65
December 108.75 3371.11
Total yearly 125872

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 160.22 4966.94
February 219.61 6149.1
March 319.83 9914.68
April 469.66 14089.9
May 511.68 15862
June 527.82 15834.5
July 566.53 17562.4
August 490.47 15204.7
September 408.04 12241
October 282.51 8757.66
November 182.33 5469.95
December 123.95 3842.52
Total yearly 129895

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 176.85 5482.33
February 235.28 6587.71
March 332.08 10294.6
April 476.66 14299.7
May 510.12 15813.6
June 522.39 15671.7
July 563.15 17457.7
August 494.3 15323.2
September 420.79 12623.6
October 299.05 9270.56
November 198.55 5956.36
December 137.87 4273.82
Total yearly 133055

Radville Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 191.85 5947.35
February 249.13 6975.59
March 342.2 10608.3
April 480.93 14427.8
May 505.9 15682.8
June 514.26 15427.9
July 556.72 17258.3
August 495.36 15356.2
September 430.87 12926.1
October 313.47 9717.43
November 213.09 6392.71
December 150.45 4664.1
Total yearly 135385

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.69% angle of incidence loss and -3.07% temperature and irradiance loss. This totals to about -15.11%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: