Solar Calculator Canada

Solar Power Calculator for Ingersoll, Ontario, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Ingersoll
  • GPS Coordinates: 43.04062, -80.87399
  • Elevation: 294 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Ingersoll: 34o
  • Average yearly irradiance: 1533.37 kWh/m2
  • Average yearly power output: 127287 kWh
Sun Path Ingersoll

Average yearly irradiance delivered by the Sun in Ingersoll is 1533.37/kWh/m2 at the optimal panel slope of 34o. After taking all losses into account, you can expect about 127287 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 34o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.06 63.87
February 2.75 77.09
March 4.22 130.81
April 5.15 154.46
May 5.77 178.75
June 6.03 181.01
July 6.02 186.55
August 5.72 177.17
September 4.83 144.96
October 3.47 107.42
November 2.65 79.55
December 1.67 51.73
Total yearly 1533.37

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 187.4 5809.38
February 249.72 6992.17
March 369.43 11452.3
April 434.4 13032.1
May 470.37 14581.3
June 481.53 14446
July 474.62 14713.3
August 453.37 14054.5
September 390.5 11715.1
October 291.23 9028.02
November 229.86 6895.74
December 147.31 4566.54
Total yearly 127287

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Ingersoll solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 147.87 4583.87
February 211.46 5920.99
March 338.36 10489.1
April 428.01 12840.3
May 489.43 15172.2
June 513.05 15391.5
July 500.98 15530.4
August 457.33 14177.3
September 367.14 11014.1
October 255.02 7905.51
November 183.77 5513.01
December 113.72 3525.39
Total yearly 122064

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 160.06 4961.94
February 223.68 6262.91
March 349.49 10834.1
April 432.99 12989.8
May 487.79 15121.4
June 507.68 15230.4
July 496.95 15405.4
August 459.85 14255.4
September 376.37 11291
October 266.93 8274.77
November 198.01 5940.44
December 123.99 3843.75
Total yearly 124411

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 171 5300.93
February 234.38 6562.51
March 358.53 11114.4
April 435.67 13070.2
May 483.63 14992.5
June 500.62 15018.5
July 491.41 15233.8
August 459.82 14254.3
September 383.41 11502.3
October 277.16 8592.04
November 210.77 6323.16
December 133.27 4131.3
Total yearly 126096

Ingersoll Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 180.65 5600.12
February 243.53 6818.89
March 365.45 11329
April 435.92 13077.7
May 477.28 14795.7
June 491.1 14733.1
July 483.17 14978.4
August 457.21 14173.7
September 388.24 11647.2
October 285.68 8856.12
November 222 6659.98
December 141.52 4387.08
Total yearly 127057

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.94% angle of incidence loss and -4.97% temperature and irradiance loss. This totals to about -16.99%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: