Solar Calculator Canada

Solar Power Calculator for Mississippi Mills, Ontario, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Mississippi Mills
  • GPS Coordinates: 45.255, -76.2875
  • Elevation: 154 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Mississippi Mills: 38o
  • Average yearly irradiance: 1563.1 kWh/m2
  • Average yearly power output: 130818 kWh
Sun Path Mississippi Mills

Average yearly irradiance delivered by the Sun in Mississippi Mills is 1563.1/kWh/m2 at the optimal panel slope of 38o. After taking all losses into account, you can expect about 130818 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 38o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.74 85.03
February 3.6 100.92
March 4.69 145.26
April 5.14 154.22
May 5.54 171.83
June 5.5 165.07
July 5.81 180.22
August 5.56 172.3
September 4.76 142.69
October 3.44 106.51
November 2.7 80.86
December 1.88 58.2
Total yearly 1563.1

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 256.02 7936.61
February 331.95 9294.59
March 415.86 12891.6
April 434.24 13027.1
May 450.7 13971.6
June 436.79 13103.8
July 456.47 14150.7
August 440.2 13646.2
September 384.32 11529.6
October 288.94 8957.16
November 235.12 7053.53
December 169.54 5255.67
Total yearly 130818

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Mississippi Mills solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 185.81 5760.08
February 265.16 7424.6
March 369.66 11459.3
April 426.59 12797.7
May 475.29 14733.9
June 474.49 14234.8
July 489.18 15164.7
August 445.57 13812.6
September 355.89 10676.7
October 243.45 7547.03
November 177.64 5329.1
December 122.19 3787.79
Total yearly 122728

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 204.21 6330.43
February 283.36 7934.05
March 383.94 11902.1
April 432.52 12975.6
May 474.28 14702.5
June 470.62 14118.5
July 486.66 15086.4
August 448.68 13909.1
September 366.02 10980.6
October 256.35 7946.95
November 192.83 5784.87
December 134.48 4168.97
Total yearly 125840

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 220.83 6845.88
February 299.47 8385.11
March 395.83 12270.6
April 436.11 13083.2
May 470.89 14597.6
June 464.22 13926.6
July 481.5 14926.5
August 449.45 13933
September 373.99 11219.6
October 267.57 8294.53
November 206.49 6194.64
December 145.61 4513.93
Total yearly 128191

Mississippi Mills Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 235.66 7305.41
February 313.46 8776.9
March 405.29 12564
April 437.35 13120.4
May 465.17 14420.3
June 455.61 13668.4
July 473.98 14693.5
August 447.88 13884.3
September 379.76 11392.8
October 277.05 8588.64
November 218.58 6557.35
December 155.55 4821.97
Total yearly 129794

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.82% angle of incidence loss and -4.31% temperature and irradiance loss. This totals to about -16.31%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Bay de VerdePort BlandfordPort RextonMusgravetownCape St. GeorgeStephenville CrossingKippensKing's CoveSaint-No�lPriceLourdesEastportSalvageGallantsRainy RiverIroquois FallsMillertownLake CowichanSt. Brendan'sHare BaySainte-Jeanne-d'ArcBadgerGlenwoodMeadowsCentreville-Wareham-TrinityMurdochville