Solar Calculator Canada

Solar Power Calculator for Eastport, Newfoundland and Labrador, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Eastport
  • GPS Coordinates: 48.6646722, -53.7676278
  • Elevation: 50 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Eastport: 38o
  • Average yearly irradiance: 1250.83 kWh/m2
  • Average yearly power output: 107439 kWh
Sun Path Eastport

Average yearly irradiance delivered by the Sun in Eastport is 1250.83/kWh/m2 at the optimal panel slope of 38o. After taking all losses into account, you can expect about 107439 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 38o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.75 54.38
February 2.5 70.11
March 3.17 98.31
April 4.32 129.51
May 4.62 143.17
June 4.91 147.44
July 5.11 158.41
August 4.51 139.7
September 3.93 117.93
October 2.69 83.51
November 2.06 61.75
December 1.5 46.61
Total yearly 1250.83

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 151.66 4701.41
February 215.31 6028.65
March 271.31 8410.58
April 368.75 11062.4
May 395.64 12264.7
June 420.5 12615
July 438.54 13594.6
August 387.82 12022.5
September 338.49 10154.8
October 232.61 7210.89
November 178.72 5361.73
December 129.39 4011.17
Total yearly 107439

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Eastport solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 110.01 3410.31
February 172.95 4842.55
March 245.12 7598.87
April 361.2 10836.1
May 410.94 12739.1
June 447.29 13418.6
July 460.66 14280.5
August 389.82 12084.5
September 312.65 9379.56
October 196.52 6092.27
November 132.78 3983.5
December 90.33 2800.31
Total yearly 101466

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 121.05 3752.66
February 184.67 5170.82
March 253.47 7857.72
April 366.21 10986.2
May 410.52 12726.2
June 444.36 13330.9
July 459.12 14232.6
August 392.7 12173.7
September 321.61 9648.34
October 206.9 6413.81
November 145.07 4352.22
December 100.58 3117.84
Total yearly 103763

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 131.06 4062.81
February 195.05 5461.5
March 260.37 8071.61
April 369.34 11080.3
May 408.45 12661.9
June 439.63 13189
July 455.8 14129.8
August 393.68 12204
September 328.75 9862.43
October 215.93 6693.72
November 156.16 4684.85
December 109.91 3407.24
Total yearly 105509

Eastport Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 140 4340.01
February 204.08 5714.13
March 265.81 8240.1
April 370.54 11116.3
May 404.99 12554.6
June 433.57 13007.1
July 450.5 13965.6
August 392.81 12177
September 334.04 10021.2
October 223.59 6931.31
November 166.02 4980.68
December 118.31 3667.57
Total yearly 106716

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -3.03% angle of incidence loss and -1.58% temperature and irradiance loss. This totals to about -14.11%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

VulcanGrenfellMorseWolseleyBirtleHerbertWhite CityShoal LakeSintalutaPilot ButteBalgonieEricksonWinnipeg BeachRiver of PondsQu'AppelleHawke's BayCabriLumsdenBurstallPort SaundersRossburnTurner ValleyBlack DiamondOkotoksLembergMurdochville