Solar Calculator Canada

Solar Power Calculator for Newbury, Ontario, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Newbury
  • GPS Coordinates: 42.69216, -81.79849
  • Elevation: 219 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Newbury: 34o
  • Average yearly irradiance: 1566.3 kWh/m2
  • Average yearly power output: 130964 kWh
Sun Path Newbury

Average yearly irradiance delivered by the Sun in Newbury is 1566.3/kWh/m2 at the optimal panel slope of 34o. After taking all losses into account, you can expect about 130964 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 34o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.06 63.83
February 2.88 80.51
March 4.32 134.01
April 5.24 157.08
May 5.8 179.84
June 6.08 182.38
July 6.12 189.75
August 5.79 179.55
September 4.92 147.73
October 3.74 115.94
November 2.72 81.59
December 1.75 54.11
Total yearly 1566.3

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 187.8 5821.86
February 262.76 7357.16
March 381.72 11833.3
April 446.72 13401.6
May 477.56 14804.5
June 488.81 14664.4
July 485.18 15040.6
August 461.71 14313.1
September 400.66 12019.9
October 315.87 9791.91
November 237.05 7111.4
December 154.99 4804.73
Total yearly 130964

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Newbury solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 149.65 4639.01
February 223.47 6257.17
March 349.95 10848.4
April 440.23 13207
May 496.83 15401.8
June 520.79 15623.8
July 512.49 15887.3
August 465.58 14432.9
September 377.02 11310.7
October 275.08 8527.54
November 190.23 5706.99
December 120.33 3730.36
Total yearly 125573

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 161.45 5004.97
February 236.07 6610.01
March 361.36 11202
April 445.35 13360.5
May 495.12 15348.8
June 515.38 15461.3
July 508.39 15760
August 468.19 14513.9
September 386.42 11592.7
October 288.45 8941.93
November 204.73 6141.97
December 130.96 4059.86
Total yearly 127998

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 172.02 5332.69
February 247.1 6918.73
March 370.62 11489.2
April 448.03 13440.8
May 491.09 15223.8
June 507.99 15239.8
July 502.38 15573.7
August 468.21 14514.6
September 393.58 11807.3
October 299.97 9298.94
November 217.72 6531.51
December 140.57 4357.52
Total yearly 129729

Newbury Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 181.34 5621.39
February 256.51 7182.34
March 377.7 11708.8
April 448.24 13447.2
May 484.64 15023.9
June 498.63 14958.8
July 493.96 15312.9
August 465.6 14433.5
September 398.44 11953.1
October 309.59 9597.25
November 229.14 6874.27
December 149.1 4622.24
Total yearly 130736

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.91% angle of incidence loss and -4.31% temperature and irradiance loss. This totals to about -16.39%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: