Solar Calculator Canada

Solar Power Calculator for Pangman, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Pangman
  • GPS Coordinates: 49.6463944, -104.659925
  • Elevation: 692 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Pangman: 42o
  • Average yearly irradiance: 1623.83 kWh/m2
  • Average yearly power output: 138183 kWh
Sun Path Pangman

Average yearly irradiance delivered by the Sun in Pangman is 1623.83/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 138183 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.3 71.25
February 3.04 85.26
March 4.04 125.37
April 5.56 166.78
May 5.8 179.87
June 5.99 179.79
July 6.65 206.19
August 6.16 190.89
September 5.35 160.56
October 3.93 121.98
November 2.58 77.51
December 1.88 58.37
Total yearly 1623.83

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 218.86 6784.8
February 286.34 8017.42
March 362.05 11223.5
April 479.9 14397.1
May 484.53 15020.6
June 487.22 14616.6
July 531.87 16487.9
August 494.15 15318.5
September 442.65 13279.4
October 340.19 10545.9
November 233.61 7008.29
December 176.86 5482.56
Total yearly 138183

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Pangman solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 139.7 4330.67
February 210.05 5881.44
March 309.04 9580.15
April 459.29 13778.8
May 509.61 15797.9
June 531.91 15957.2
July 566.98 17576.3
August 489.47 15173.7
September 391.03 11730.8
October 263.82 8178.34
November 158.95 4768.65
December 108.7 3369.77
Total yearly 126124

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 157.74 4890.02
February 228.3 6392.39
March 323.7 10034.6
April 469.08 14072.4
May 510.83 15835.9
June 529.92 15897.5
July 567.36 17588.2
August 496.3 15385.3
September 406.44 12193.1
October 282.61 8761.05
November 176.31 5289.21
December 124.12 3847.79
Total yearly 130187

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 174.21 5400.64
February 244.7 6851.58
March 336.23 10423.1
April 476.17 14285.2
May 509.22 15785.8
June 524.48 15734.5
July 564.15 17488.6
August 500.32 15509.9
September 419.23 12576.8
October 299.32 9278.99
November 192.09 5762.65
December 138.24 4285.35
Total yearly 133383

Pangman Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 189.08 5861.57
February 259.21 7258
March 346.6 10744.5
April 480.54 14416.2
May 504.95 15653.3
June 516.34 15490.1
July 557.87 17293.9
August 501.53 15547.5
September 429.35 12880.6
October 313.89 9730.61
November 206.26 6187.71
December 151.02 4681.54
Total yearly 135746

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.7% angle of incidence loss and -2.83% temperature and irradiance loss. This totals to about -14.9%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

KelliherLestockWisetonMacrorieDinsmoreRheinEbenezerPunnichyBeisekerTogoSemansTheodoreBrockSimpsonFlaxcombeCarbonMildenAcmeKenastonYoungstownEthelbertConquestCremonaMunsonShehoMurdochville