Solar Calculator Canada

Solar Power Calculator for Pembroke, Ontario, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Pembroke
  • GPS Coordinates: 45.8205556, -77.1111111
  • Elevation: 127 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Pembroke: 38o
  • Average yearly irradiance: 1523.83 kWh/m2
  • Average yearly power output: 127527 kWh
Sun Path Pembroke

Average yearly irradiance delivered by the Sun in Pembroke is 1523.83/kWh/m2 at the optimal panel slope of 38o. After taking all losses into account, you can expect about 127527 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 38o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.52 78.16
February 3.35 93.71
March 4.46 138.17
April 5.03 151.04
May 5.53 171.45
June 5.58 167.31
July 5.81 180.16
August 5.58 172.92
September 4.62 138.49
October 3.26 100.99
November 2.53 75.99
December 1.79 55.43
Total yearly 1523.83

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 236.1 7319.03
February 308.89 8648.99
March 396.6 12294.6
April 426.56 12796.9
May 449.75 13942.1
June 443.38 13301.4
July 456.69 14157.3
August 442.29 13711
September 373.42 11202.7
October 273.88 8490.19
November 221.06 6631.81
December 162.28 5030.7
Total yearly 127527

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Pembroke solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 170.41 5282.7
February 246.46 6900.86
March 351.99 10911.7
April 418.38 12551.3
May 472.14 14636.3
June 478.57 14357
July 487.9 15124.8
August 445.03 13796
September 345.13 10353.8
October 231.69 7182.43
November 166.65 4999.52
December 116.1 3599.04
Total yearly 119696

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 187.62 5816.33
February 263.48 7377.5
March 365.81 11340.1
April 424.32 12729.7
May 471.58 14618.9
June 475.24 14257.1
July 485.61 15054
August 448.7 13909.6
September 355.08 10652.5
October 243.73 7555.55
November 181.02 5430.66
December 128.15 3972.79
Total yearly 122715

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 203.17 6298.17
February 278.56 7799.65
March 377.34 11697.4
April 427.98 12839.3
May 468.63 14527.6
June 469.39 14081.6
July 480.67 14900.7
August 450.01 13950.3
September 362.94 10888.2
October 254.17 7879.26
November 193.96 5818.82
December 139.06 4310.76
Total yearly 124992

Pembroke Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 217.02 6727.56
February 291.66 8166.51
March 386.54 11982.8
April 429.34 12880.2
May 463.36 14364.2
June 461.31 13839.2
July 473.37 14674.6
August 448.96 13917.9
September 368.68 11060.3
October 262.99 8152.6
November 205.43 6162.86
December 148.79 4612.53
Total yearly 126541

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.82% angle of incidence loss and -4.31% temperature and irradiance loss. This totals to about -16.31%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

HawkesburyPort HawkesburyAntigonishSussexAmherstOromoctoFort-CoulongeGore BaySackvilleDeep RiverWoodstockMontagueShediacEspanolaThessalonMattawaSourisBouctoucheTrepasseyFerrylandGrand FallsGrand-SaultBurinGrand BankMarystownMurdochville