Solar Calculator Canada

Solar Power Calculator for Ferryland, Newfoundland and Labrador, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Ferryland
  • GPS Coordinates: 47.0302389, -52.9056278
  • Elevation: 106 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Ferryland: 37o
  • Average yearly irradiance: 1272.87 kWh/m2
  • Average yearly power output: 109284 kWh
Sun Path Ferryland

Average yearly irradiance delivered by the Sun in Ferryland is 1272.87/kWh/m2 at the optimal panel slope of 37o. After taking all losses into account, you can expect about 109284 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 37o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.6 49.58
February 2.27 63.55
March 3.09 95.84
April 4.37 131.05
May 4.74 146.88
June 4.97 149.12
July 5.13 159.08
August 4.61 142.82
September 4.18 125.31
October 2.96 91.66
November 2.19 65.77
December 1.68 52.21
Total yearly 1272.87

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 144.78 4488.24
February 205.95 5766.6
March 277.45 8600.86
April 383.9 11516.9
May 406.89 12613.5
June 418.99 12569.6
July 423.12 13116.6
August 378.19 11723.7
September 349.82 10494.6
October 254.75 7897.25
November 193.51 5805.23
December 151.31 4690.66
Total yearly 109284

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Ferryland solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 107.59 3335.36
February 169.58 4748.26
March 253.02 7843.65
April 376.54 11296.2
May 425.41 13187.9
June 447.57 13427
July 445.58 13812.8
August 379.75 11772.2
September 323.32 9699.48
October 215.1 6668.03
November 145.7 4371.15
December 106.11 3289.27
Total yearly 103451

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 117.69 3648.25
February 179.95 5038.52
March 261.15 8095.63
April 381.75 11452.6
May 424.18 13149.6
June 443.96 13318.7
July 443.63 13752.5
August 382.77 11865.9
September 332.72 9981.55
October 226.69 7027.46
November 158.76 4762.78
December 118.19 3664.01
Total yearly 105758

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 126.85 3932.3
February 189.11 5295.22
March 267.79 8301.63
April 384.84 11545.2
May 421.29 13060
June 438.48 13154.2
July 439.9 13637
August 383.8 11897.8
September 340.16 10204.9
October 236.82 7341.34
November 170.58 5117.41
December 129.27 4007.26
Total yearly 107494

Ferryland Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 135.04 4186.38
February 197.04 5517.25
March 272.93 8460.69
April 385.85 11575.6
May 417 12927.1
June 431.83 12954.8
July 434.23 13461.2
August 382.88 11869.4
September 345.62 10368.6
October 245.43 7608.32
November 181.12 5433.64
December 139.28 4317.54
Total yearly 108680

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -3.05% angle of incidence loss and -1.6% temperature and irradiance loss. This totals to about -14.14%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: