Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Alberton
  • GPS Coordinates: 46.812804, -64.065297
  • Elevation: 7 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Alberton: 37o
  • Average yearly irradiance: 1413.5 kWh/m2
  • Average yearly power output: 121958 kWh
Sun Path Alberton

Average yearly irradiance delivered by the Sun in Alberton is 1413.5/kWh/m2 at the optimal panel slope of 37o. After taking all losses into account, you can expect about 121958 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 37o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.81 56.19
February 2.83 79.13
March 3.79 117.4
April 4.86 145.94
May 5.4 167.54
June 5.38 161.51
July 5.72 177.22
August 5.47 169.55
September 4.73 141.94
October 3.34 103.59
November 1.92 57.48
December 1.16 36.02
Total yearly 1413.5

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 169.04 5240.16
February 264.87 7416.4
March 346.21 10732.6
April 431.45 12943.6
May 466.28 14454.7
June 450.96 13528.8
July 468.28 14516.6
August 449.35 13930
September 399.15 11974.5
October 290.02 8990.52
November 168.32 5049.55
December 102.59 3180.26
Total yearly 121958

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Alberton solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 124.31 3853.63
February 210.45 5892.54
March 308.69 9569.38
April 420.04 12601.3
May 483.44 14986.7
June 481.74 14452.1
July 492.64 15271.8
August 448.16 13892.9
September 364.24 10927.3
October 242.03 7503.01
November 130.27 3908.14
December 76.59 2374.33
Total yearly 115233

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 136.4 4228.28
February 225.71 6320.02
March 320.73 9942.56
April 426.63 12798.8
May 483.71 14994.9
June 478.1 14343
July 490.82 15215.5
August 452.64 14031.9
September 376.15 11284.4
October 255.93 7933.92
November 140.71 4221.36
December 83.62 2592.34
Total yearly 117907

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 147.35 4567.92
February 239.31 6700.8
March 330.77 10253.8
April 430.87 12926
May 481.37 14922.6
June 472.82 14184.5
July 487.13 15100.9
August 454.67 14094.8
September 385.74 11572.1
October 268.11 8311.52
November 150.13 4503.86
December 90.01 2790.23
Total yearly 119929

Alberton Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 157.14 4871.49
February 251.2 7033.68
March 338.77 10501.9
April 432.74 12982.3
May 476.55 14773
June 464.89 13946.7
July 480.71 14901.9
August 454.31 14083.7
September 392.95 11788.6
October 278.53 8634.29
November 158.48 4754.38
December 95.71 2967.15
Total yearly 121239

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.84% angle of incidence loss and -1.33% temperature and irradiance loss. This totals to about -13.72%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: