Solar Calculator Canada

Solar Power Calculator for Barford, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Barford
  • GPS Coordinates: 45.1161111, -71.7955556
  • Elevation: 290 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Barford: 37o
  • Average yearly irradiance: 1440.54 kWh/m2
  • Average yearly power output: 121206 kWh
Sun Path Barford

Average yearly irradiance delivered by the Sun in Barford is 1440.54/kWh/m2 at the optimal panel slope of 37o. After taking all losses into account, you can expect about 121206 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 37o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.46 76.12
February 2.95 82.62
March 3.94 122.29
April 4.71 141.35
May 5.13 158.97
June 5.15 154.56
July 5.57 172.76
August 5.29 164.11
September 4.62 138.49
October 3.27 101.23
November 2.51 75.45
December 1.7 52.58
Total yearly 1440.54

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 229.38 7110.64
February 271.71 7607.93
March 350.11 10853.3
April 401.2 12036
May 421.93 13079.8
June 414.25 12427.5
July 443.8 13757.8
August 424.45 13158
September 375.7 11270.9
October 275.99 8555.55
November 220.1 6603.08
December 153.07 4745.11
Total yearly 121206

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Barford solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 169.06 5240.97
February 222.19 6221.36
March 315.55 9782.2
April 395.33 11859.9
May 442.43 13715.5
June 446.48 13394.3
July 472.17 14637.4
August 428.9 13295.9
September 349.95 10498.6
October 234.14 7258.44
November 168.39 5051.57
December 110.24 3417.55
Total yearly 114374

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 185.38 5746.81
February 236.21 6613.75
March 326.85 10132.4
April 400.24 12007.3
May 441.44 13684.5
June 442.74 13282.3
July 469.56 14556.3
August 431.61 13379.8
September 359.5 10785.1
October 246.4 7638.51
November 182.53 5476.01
December 121.72 3773.44
Total yearly 117076

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 200.13 6204.1
February 248.54 6959.22
March 336.16 10420.9
April 403.03 12091
May 438.18 13583.6
June 436.75 13102.5
July 464.54 14400.7
August 432.1 13395.2
September 366.95 11008.4
October 257.04 7968.28
November 195.23 5856.94
December 132.14 4096.36
Total yearly 119087

Barford Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 213.28 6611.59
February 259.18 7257.03
March 343.44 10646.8
April 403.82 12114.6
May 432.83 13417.7
June 428.73 12862
July 457.29 14175.9
August 430.42 13343.2
September 372.26 11167.7
October 266.02 8246.73
November 206.45 6193.54
December 141.46 4385.3
Total yearly 120422

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.94% angle of incidence loss and -3.68% temperature and irradiance loss. This totals to about -15.86%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Murdochville