Solar Calculator Canada

Solar Power Calculator for Whiteway, Newfoundland and Labrador, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Whiteway
  • GPS Coordinates: 47.683011, -53.451008
  • Elevation: 130 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Whiteway: 36o
  • Average yearly irradiance: 1224.11 kWh/m2
  • Average yearly power output: 105587 kWh
Sun Path Whiteway

Average yearly irradiance delivered by the Sun in Whiteway is 1224.11/kWh/m2 at the optimal panel slope of 36o. After taking all losses into account, you can expect about 105587 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 36o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.35 41.83
February 2.13 59.51
March 3.01 93.24
April 4.39 131.71
May 4.78 148.11
June 4.94 148.11
July 4.99 154.6
August 4.52 140.13
September 4.14 124.32
October 2.75 85.28
November 1.89 56.82
December 1.3 40.45
Total yearly 1224.11

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 121.42 3764.12
February 193.25 5410.99
March 271.19 8406.98
April 389.54 11686.1
May 414.69 12855.2
June 418.34 12550.2
July 414.53 12850.4
August 374.26 11602.2
September 349.86 10495.9
October 237.46 7361.36
November 166.93 5007.91
December 115.97 3595.09
Total yearly 105587

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Whiteway solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 93.06 2884.75
February 160.41 4491.59
March 246.96 7655.76
April 380.43 11413
May 429.15 13303.6
June 444.54 13336.2
July 433.4 13435.3
August 373.55 11580.2
September 321.66 9649.73
October 200.96 6229.77
November 127.56 3826.75
December 85.83 2660.74
Total yearly 100467

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 101.08 3133.34
February 170.06 4761.63
March 255.07 7907.13
April 386.04 11581.1
May 428.53 13284.6
June 441.11 13233.3
July 431.57 13378.7
August 376.62 11675.3
September 331.5 9944.86
October 211.75 6564.22
November 138.56 4156.71
December 94.32 2923.85
Total yearly 102545

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 108.3 3357.37
February 178.55 4999.46
March 261.72 8113.43
April 389.58 11687.4
May 426.13 13209.9
June 435.8 13074.1
July 428 13268.1
August 377.8 11711.8
September 339.35 10180.5
October 221.15 6855.76
November 148.47 4454.24
December 101.99 3161.8
Total yearly 104074

Whiteway Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 114.72 3556.27
February 185.87 5204.34
March 266.89 8273.71
April 390.97 11729
May 422.23 13089.3
June 429.23 12876.9
July 422.48 13096.9
August 377.08 11689.3
September 345.19 10355.6
October 229.14 7103.29
November 157.28 4718.45
December 108.85 3374.3
Total yearly 105067

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -3.01% angle of incidence loss and -1.18% temperature and irradiance loss. This totals to about -13.74%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Saint-Remi-d'AmherstSainte-MargueriteSaint-Z�phirin-de-CourvalSaint-Th�odoreVend�eLa VisitationLac-CayamantSainte-Sophie-de-M�ganticLac-LabelleSainte-Th�r�se-de-la-GatineauLourdesLac-CastorSaint-Thomas-de-CaxtonHunterstownSaint-NarcisseJolyBrunetSaint-Jean-sur-le-LacIssoudunDaaquamVal-LimogesSainte-FloreBucklandLes �cureuilsJacques-CartierMurdochville