Solar Calculator Canada

Solar Power Calculator for Beauharnois, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Beauharnois
  • GPS Coordinates: 45.313216, -73.877952
  • Elevation: 34 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Beauharnois: 39o
  • Average yearly irradiance: 1565.13 kWh/m2
  • Average yearly power output: 131658 kWh
Sun Path Beauharnois

Average yearly irradiance delivered by the Sun in Beauharnois is 1565.13/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 131658 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.7 83.66
February 3.27 91.57
March 4.4 136.34
April 5.06 151.83
May 5.58 172.9
June 5.55 166.55
July 5.92 183.63
August 5.82 180.35
September 4.88 146.37
October 3.43 106.43
November 2.85 85.39
December 1.94 60.12
Total yearly 1565.13

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 253.39 7855.01
February 302.86 8480.16
March 392.13 12156.2
April 430.89 12926.8
May 456.58 14154.1
June 443.75 13312.5
July 468.52 14524.2
August 464.42 14396.9
September 395.81 11874.4
October 290.11 8993.38
November 250.24 7507.2
December 176.67 5476.72
Total yearly 131658

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Beauharnois solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 179.91 5577.09
February 240.14 6723.98
March 347.6 10775.7
April 423.15 12694.4
May 480.66 14900.4
June 481.36 14440.7
July 501.71 15552.9
August 467.95 14506.4
September 365.28 10958.5
October 242.64 7521.75
November 186.64 5599.08
December 123.72 3835.36
Total yearly 123086

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 198.65 6158.1
February 256.94 7194.45
March 361.27 11199.4
April 429.16 12874.8
May 480.15 14884.8
June 477.95 14338.5
July 499.42 15482.1
August 471.96 14630.9
September 375.98 11279.3
October 255.87 7931.96
November 203.12 6093.52
December 137.16 4251.9
Total yearly 126320

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 215.66 6685.41
February 271.84 7611.4
March 372.67 11552.9
April 432.86 12985.7
May 477.18 14792.5
June 471.99 14159.8
July 494.61 15333
August 473.46 14677.1
September 384.42 11532.6
October 267.4 8289.26
November 217.96 6538.77
December 149.38 4630.85
Total yearly 128789

Beauharnois Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 230.89 7157.53
February 284.78 7973.96
March 381.77 11835
April 434.22 13026.5
May 471.79 14625.6
June 463.74 13912.3
July 487.31 15106.7
August 472.42 14645
September 390.57 11717.2
October 277.18 8592.46
November 231.13 6933.76
December 160.36 4971.15
Total yearly 130497

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.74% angle of incidence loss and -3.9% temperature and irradiance loss. This totals to about -15.88%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Halton HillsLockeportNorth PerthAjaxCaledonRichmond HillMarkhamPickeringOrangevilleMintoWhitbyAuroraWhitchurch-StouffvilleMonoShelburneNew TecumsethBradford West GwillimburyEast GwillimburyHanoverDeserontoGreater NapaneeInnisfilGeorginaSaugeen ShoresMahone BayMurdochville