Solar Calculator Canada

Solar Power Calculator for Mono, Ontario, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Mono
  • GPS Coordinates: 44.01739, -80.0581
  • Elevation: 464 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Mono: 36o
  • Average yearly irradiance: 1559.21 kWh/m2
  • Average yearly power output: 130618 kWh
Sun Path Mono

Average yearly irradiance delivered by the Sun in Mono is 1559.21/kWh/m2 at the optimal panel slope of 36o. After taking all losses into account, you can expect about 130618 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 36o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.36 73.16
February 3.15 88.12
March 4.51 139.83
April 5.18 155.48
May 5.71 177.07
June 5.77 173.1
July 6.05 187.69
August 5.64 174.95
September 4.84 145.16
October 3.42 105.97
November 2.71 81.35
December 1.85 57.32
Total yearly 1559.21

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 217.8 6751.66
February 289.41 8103.55
March 399.55 12386.1
April 440.01 13200.2
May 468.14 14512.3
June 462.4 13872.1
July 480 14880
August 449.68 13940.1
September 392.8 11783.9
October 288.48 8943
November 237 7110.03
December 165.63 5134.64
Total yearly 130618

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Mono solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 166.69 5167.39
February 239.65 6710.06
March 361.12 11194.6
April 433.59 13007.6
May 490.24 15197.5
June 496.95 14908.4
July 510.03 15810.9
August 454.47 14088.7
September 366.81 11004.3
October 248.6 7706.54
November 184.49 5534.76
December 122.44 3795.75
Total yearly 124127

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 181.32 5620.93
February 254.4 7123.14
March 373.99 11593.7
April 438.91 13167.2
May 488.79 15152.5
June 491.91 14757.2
July 506.21 15692.6
August 457.27 14175.2
September 376.59 11297.8
October 260.86 8086.54
November 199.55 5986.64
December 134.65 4174.27
Total yearly 126828

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 194.47 6028.57
February 267.39 7486.91
March 384.57 11921.7
April 441.9 13257.1
May 484.74 15026.9
June 485.24 14557.1
July 500.75 15523.1
August 457.67 14187.7
September 384.16 11524.7
October 271.44 8414.71
November 213.09 6392.66
December 145.74 4517.81
Total yearly 128839

Mono Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 206.11 6389.5
February 278.58 7800.31
March 392.83 12177.8
April 442.48 13274.3
May 478.35 14829
June 475.85 14275.6
July 492.85 15278.3
August 455.43 14118.3
September 389.47 11684.1
October 280.32 8689.87
November 225.05 6751.45
December 155.65 4825.14
Total yearly 130094

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.94% angle of incidence loss and -4.1% temperature and irradiance loss. This totals to about -16.23%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

GaultoisRose Blanche-Harbour Le CouPortugal Cove-St. Philip'sRencontre EastWabanaEnglish Harbour EastTorbayTerrencevilleChance CoveHarbour GraceFlatrockBeresfordSouthern HarbourPouch CoveArnold's CoveVictoriaGrand Le PierreLam�queCome By ChanceHeart's ContentSunnysideMilltown-Head of Bay d'EspoirWintertonHant's HarbourOld PerlicanMurdochville