Solar Calculator Canada

Solar Power Calculator for Bedford, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Bedford
  • GPS Coordinates: 45.1166667, -72.9833333
  • Elevation: 54 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Bedford: 37o
  • Average yearly irradiance: 1475.37 kWh/m2
  • Average yearly power output: 123095 kWh
Sun Path Bedford

Average yearly irradiance delivered by the Sun in Bedford is 1475.37/kWh/m2 at the optimal panel slope of 37o. After taking all losses into account, you can expect about 123095 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 37o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.44 75.5
February 2.97 83.23
March 4.12 127.66
April 4.74 142.18
May 5.36 166.04
June 5.32 159.57
July 5.76 178.61
August 5.56 172.22
September 4.67 139.96
October 3.2 99.18
November 2.59 77.73
December 1.73 53.5
Total yearly 1475.37

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 226 7006.01
February 272.05 7617.31
March 363.86 11279.7
April 400.48 12014.3
May 436.64 13535.9
June 423.75 12712.4
July 453.76 14066.6
August 440.92 13668.6
September 376.53 11296
October 268.41 8320.61
November 225.65 6769.41
December 155.09 4807.92
Total yearly 123095

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Bedford solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 166.04 5147.27
February 221.79 6210
March 326.45 10119.8
April 394.1 11822.9
May 456.74 14159
June 456.7 13701.2
July 482.73 14964.5
August 444.02 13764.7
September 349.8 10494.1
October 227.61 7055.85
November 172.11 5163.26
December 111.73 3463.52
Total yearly 116066

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 182.17 5647.18
February 235.98 6607.37
March 338.44 10491.5
April 399.14 11974.3
May 456.11 14139.5
June 453.22 13596.7
July 480.36 14891.2
August 447.41 13869.6
September 359.54 10786.1
October 239.46 7423.41
November 186.63 5598.89
December 123.28 3821.61
Total yearly 118847

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 196.75 6099.12
February 248.48 6957.42
March 348.35 10798.8
April 402.08 12062.2
May 453.16 14048.1
June 447.34 13420.3
July 475.59 14743.2
August 448.44 13901.7
September 367.15 11014.6
October 249.75 7742.38
November 199.67 5990.12
December 133.76 4146.53
Total yearly 120925

Bedford Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 209.74 6501.96
February 259.27 7259.49
March 356.16 11040.9
April 402.87 12086.2
May 447.99 13887.7
June 439.34 13180.2
July 468.48 14522.8
August 447.13 13861
September 372.64 11179.1
October 258.44 8011.7
November 211.2 6336.09
December 143.14 4437.36
Total yearly 122305

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.84% angle of incidence loss and -4.59% temperature and irradiance loss. This totals to about -16.57%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Halton HillsLockeportNorth PerthAjaxCaledonRichmond HillMarkhamPickeringOrangevilleMintoWhitbyAuroraWhitchurch-StouffvilleMonoShelburneNew TecumsethBradford West GwillimburyEast GwillimburyHanoverDeserontoGreater NapaneeInnisfilGeorginaSaugeen ShoresMahone BayMurdochville