Solar Calculator Canada

Solar Power Calculator for Belleterre, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Belleterre
  • GPS Coordinates: 47.3833334, -78.7
  • Elevation: 311 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Belleterre: 40o
  • Average yearly irradiance: 1485.18 kWh/m2
  • Average yearly power output: 126346 kWh
Sun Path Belleterre

Average yearly irradiance delivered by the Sun in Belleterre is 1485.18/kWh/m2 at the optimal panel slope of 40o. After taking all losses into account, you can expect about 126346 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 40o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.66 82.61
February 3.77 105.67
March 4.84 149.89
April 4.94 148.09
May 5.4 167.26
June 5.44 163.26
July 5.52 171.2
August 5.16 159.88
September 4.34 130.3
October 2.95 91.41
November 2.04 61.26
December 1.75 54.35
Total yearly 1485.18

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 255.78 7929.16
February 357.21 10001.8
March 438.23 13585.2
April 424.22 12726.7
May 444.1 13767
June 436.87 13106.2
July 439.51 13624.8
August 413.36 12814.3
September 355.35 10660.5
October 249.64 7738.72
November 178.87 5365.99
December 162.11 5025.32
Total yearly 126346

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Belleterre solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 178.14 5522.37
February 276.19 7733.21
March 381.51 11826.8
April 414.34 12430.2
May 466.61 14465
June 474.22 14226.5
July 470.28 14578.6
August 416.59 12914.2
September 326.05 9781.44
October 209.33 6489.17
November 133.76 4012.7
December 111.88 3468.18
Total yearly 117448

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 197.35 6117.83
February 297.01 8316.26
March 398.04 12339.2
April 420.87 12626
May 466.74 14468.8
June 470.69 14120.8
July 468.15 14512.6
August 420.34 13030.7
September 335.96 10078.8
October 220.34 6830.58
November 145.1 4353.06
December 124.27 3852.51
Total yearly 120647

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 214.77 6657.87
February 315.59 8836.61
March 412.03 12772.8
April 425.14 12754.1
May 464.37 14395.6
June 465.6 13968
July 464.44 14397.6
August 421.84 13077
September 343.89 10316.6
October 229.92 7127.45
November 155.34 4660.06
December 135.53 4201.5
Total yearly 123165

Belleterre Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 230.37 7141.52
February 331.89 9293.02
March 423.43 13126.5
April 427.14 12814.3
May 459.68 14250.1
June 457.91 13737.4
July 458.11 14201.5
August 421.28 13059.6
September 349.77 10493.1
October 238.03 7378.79
November 164.42 4932.55
December 145.63 4514.51
Total yearly 124943

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.84% angle of incidence loss and -2.71% temperature and irradiance loss. This totals to about -14.93%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Nipissing OuestWest NipissingFlorenceville-BristolNorth RusticoMarkstay-WarrenLaurier-StationRichibuctoPortugal Cove SouthO'LearySt. Vincent's-St. Stephen's-Peter's RiverAlbertonSainte-P�tronilleBranchLord's CoveLamalineSt. LawrenceSt. Mary'sSt. Bride'sLawnPoint MayFermeuseRiverheadAdmirals BeachFortuneTemagamiMurdochville