Solar Calculator Canada

Solar Power Calculator for Carillon, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Carillon
  • GPS Coordinates: 45.5694444, -74.375
  • Elevation: 31 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Carillon: 39o
  • Average yearly irradiance: 1557.25 kWh/m2
  • Average yearly power output: 130510 kWh
Sun Path Carillon

Average yearly irradiance delivered by the Sun in Carillon is 1557.25/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 130510 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.65 82.16
February 3.3 92.43
March 4.52 140.07
April 5.12 153.49
May 5.54 171.85
June 5.49 164.68
July 5.85 181.22
August 5.67 175.86
September 4.8 144.09
October 3.41 105.77
November 2.83 84.84
December 1.96 60.8
Total yearly 1557.25

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 247.41 7669.6
February 304.34 8521.58
March 401.13 12435
April 433.37 13001
May 451.79 14005.4
June 436.33 13089.8
July 460.11 14263.5
August 450.83 13975.8
September 388.7 11661
October 287.59 8915.43
November 248.04 7441.18
December 178.41 5530.84
Total yearly 130510

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Carillon solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 176.45 5470.04
February 242.69 6795.37
March 355.74 11028
April 425.18 12755.5
May 475.88 14752.3
June 473.97 14219.2
July 493.43 15296.3
August 454.49 14089.1
September 358.77 10763.1
October 240.35 7450.81
November 184.88 5546.51
December 124.7 3865.69
Total yearly 122032

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 194.68 6035.03
February 259.31 7260.67
March 369.7 11460.6
April 431.25 12937.4
May 475.16 14730.1
June 470.42 14112.7
July 490.95 15219.4
August 458.27 14206.4
September 369.29 11078.6
October 253.53 7859.31
November 201.27 6038.09
December 138.37 4289.61
Total yearly 125228

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 211.18 6546.72
February 274.01 7672.19
March 381.33 11821.2
April 434.97 13049.1
May 472.06 14633.7
June 464.39 13931.7
July 486.01 15066.2
August 459.63 14248.4
September 377.6 11327.8
October 265.01 8215.23
November 216.02 6480.57
December 150.79 4674.44
Total yearly 127667

Carillon Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 225.93 7003.93
February 286.76 8029.25
March 390.61 12109
April 436.34 13090
May 466.59 14464.3
June 456.11 13683.4
July 478.65 14838.1
August 458.55 14215
September 383.67 11510.1
October 274.76 8517.45
November 229.1 6872.98
December 161.92 5019.39
Total yearly 129353

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.77% angle of incidence loss and -4.23% temperature and irradiance loss. This totals to about -16.19%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

South RiverNorth RiverNorman's Cove-Long CoveLittle Bay EastBurnt IslandsLogy Bay-Middle Cove-Outer CoveUpper Island CovePool's CoveWhitewayBaulineHeart's Delight-IslingtonSalmon CoveHeart's DesireSmall Point-Adam's Cove-Blackhead-Broad CoveMorrisvilleNew PerlicanSaint-Andr�-du-Lac-Saint-JeanTrinityH�bertville-StationView RoyalTerra NovaPort au Port EastDuntaraKeelsEllistonMurdochville