Solar Calculator Canada

Solar Power Calculator for Carleton-sur-Mer, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Carleton-sur-Mer
  • GPS Coordinates: 48.104, -66.126
  • Elevation: 9 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Carleton-sur-Mer: 39o
  • Average yearly irradiance: 1408.77 kWh/m2
  • Average yearly power output: 119817 kWh
Sun Path Carleton-sur-Mer

Average yearly irradiance delivered by the Sun in Carleton-sur-Mer is 1408.77/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 119817 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.15 66.73
February 2.99 83.69
March 3.97 123.14
April 4.77 143.16
May 5.17 160.36
June 5.29 158.61
July 5.5 170.4
August 5.18 160.47
September 4.5 134.99
October 3.12 96.68
November 2.04 61.24
December 1.59 49.29
Total yearly 1408.77

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 204.94 6353.14
February 280.75 7860.99
March 359.83 11154.8
April 414.63 12439
May 431.49 13376.2
June 427.96 12838.8
July 438.57 13595.6
August 415.5 12880.6
September 370.87 11126.2
October 266.79 8270.6
November 179.74 5392.26
December 146.09 4528.79
Total yearly 119817

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Carleton-sur-Mer solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 144.19 4469.88
February 220.72 6180.15
March 318.47 9872.42
April 403.24 12097.2
May 449.65 13939.1
June 459.98 13799.5
July 464.53 14400.5
August 415.54 12881.9
September 336.64 10099.1
October 220.21 6826.52
November 133.06 3991.75
December 101.11 3134.29
Total yearly 111692

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 159.32 4938.93
February 236.38 6618.69
March 330.88 10257.4
April 409.88 12296.4
May 450.07 13952.1
June 457.11 13713.4
July 463.12 14356.8
August 419.84 13015.2
September 347.82 10434.6
October 232.85 7218.4
November 144.9 4347.14
December 112.24 3479.58
Total yearly 114629

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 173.1 5366.07
February 250.34 7009.6
March 341.3 10580.3
April 414.33 12429.9
May 448.5 13903.7
June 452.24 13567.2
July 459.63 14248.5
August 422.13 13086
September 356.88 10706.5
October 243.92 7561.65
November 155.6 4667.9
December 122.42 3794.97
Total yearly 116922

Carleton-sur-Mer Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 185.48 5749.92
February 262.56 7351.71
March 349.68 10840.2
April 416.58 12497.4
May 444.68 13784.9
June 445.86 13375.7
July 454.56 14091.5
August 422.05 13083.5
September 363.79 10913.8
October 253.4 7855.27
November 165.1 4953.13
December 131.59 4079.27
Total yearly 118576

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.84% angle of incidence loss and -2.74% temperature and irradiance loss. This totals to about -14.95%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Nipissing OuestWest NipissingFlorenceville-BristolNorth RusticoMarkstay-WarrenLaurier-StationRichibuctoPortugal Cove SouthO'LearySt. Vincent's-St. Stephen's-Peter's RiverAlbertonSainte-P�tronilleBranchLord's CoveLamalineSt. LawrenceSt. Mary'sSt. Bride'sLawnPoint MayFermeuseRiverheadAdmirals BeachFortuneTemagamiMurdochville