Solar Calculator Canada

Solar Power Calculator for Chevery, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Chevery
  • GPS Coordinates: 50.468611, -59.616111
  • Elevation: 2 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Chevery: 37o
  • Average yearly irradiance: 1212.68 kWh/m2
  • Average yearly power output: 103653 kWh
Sun Path Chevery

Average yearly irradiance delivered by the Sun in Chevery is 1212.68/kWh/m2 at the optimal panel slope of 37o. After taking all losses into account, you can expect about 103653 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 37o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.09 33.73
February 1.86 51.95
March 2.77 85.76
April 3.95 118.59
May 5.01 155.39
June 5.21 156.16
July 5.2 161.29
August 4.78 148.03
September 3.96 118.94
October 3.08 95.54
November 1.83 55.02
December 1.04 32.29
Total yearly 1212.68

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 91.02 2821.75
February 156.11 4371
March 233.73 7245.48
April 336.15 10084.6
May 427.82 13262.4
June 444.72 13341.5
July 445.23 13802.1
August 409.64 12698.7
September 341.2 10236
October 267.29 8286.13
November 158.83 4764.92
December 88.34 2738.46
Total yearly 103653

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Chevery solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 68.27 2116.31
February 127.12 3559.26
March 210.29 6518.93
April 328.15 9844.44
May 440.1 13643.2
June 468.76 14062.8
July 463.17 14358.4
August 406.45 12599.9
September 310.68 9320.32
October 218.4 6770.3
November 117.27 3518.08
December 63.17 1958.25
Total yearly 98270.2

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 74.57 2311.62
February 135.44 3792.36
March 217.88 6754.28
April 332.72 9981.62
May 440.89 13667.7
June 467.07 14012.2
July 462.87 14349
August 410.59 12728.4
September 320.85 9625.41
October 232.44 7205.79
November 128.72 3861.48
December 70 2170.15
Total yearly 100460

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 80.23 2487
February 142.76 3997.18
March 224.17 6949.23
April 335.61 10068.4
May 439.4 13621.3
June 462.99 13889.5
July 460.17 14265.2
August 412.66 12792.6
September 329.12 9873.7
October 244.84 7590.11
November 139.06 4171.72
December 76.22 2362.85
Total yearly 102069

Chevery Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 85.23 2642.24
February 149.06 4173.72
March 229.15 7103.7
April 336.83 10104.9
May 435.81 13510.2
June 456.58 13697.5
July 455.2 14111.2
August 412.66 12792.6
September 335.49 10064.7
October 255.57 7922.53
November 148.28 4448.26
December 81.8 2535.76
Total yearly 103107

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -3.01% angle of incidence loss and -2.08% temperature and irradiance loss. This totals to about -14.53%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Lac-BromeSaint-R�miWatervilleFarnhamBeauharnoisBromontWaterlooCh�teauguayVaudreuil-DorionSaint-C�saireCookshire-EatonLa PrairieMarievilleChamblyHudsonRigaudEast AngusClarence-RocklandSaint-PieValcourtLongueuilScotstownLavalSaint-EustacheWindsorMurdochville