Solar Calculator Canada

Solar Power Calculator for Daaquam, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Daaquam
  • GPS Coordinates: 46.5880556, -70.0633333
  • Elevation: 363 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Daaquam: 41o
  • Average yearly irradiance: 1502.24 kWh/m2
  • Average yearly power output: 128229 kWh
Sun Path Daaquam

Average yearly irradiance delivered by the Sun in Daaquam is 1502.24/kWh/m2 at the optimal panel slope of 41o. After taking all losses into account, you can expect about 128229 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 41o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 3.17 98.33
February 3.72 104.2
March 4.42 137.11
April 4.85 145.53
May 4.93 152.97
June 5.12 153.69
July 5.48 169.96
August 5.18 160.54
September 4.5 135.05
October 3.26 101.04
November 2.56 76.72
December 2.16 67.09
Total yearly 1502.24

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 303.19 9398.89
February 349.59 9788.61
March 398.89 12365.5
April 417.54 12526.2
May 407.96 12646.8
June 412.27 12368
July 436.68 13537
August 415.5 12880.3
September 368.53 11055.8
October 277.82 8612.37
November 227.14 6814.3
December 201.12 6234.75
Total yearly 128229

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Daaquam solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 206.33 6396.21
February 270.6 7576.86
March 351.97 10910.9
April 410.72 12321.7
May 433.57 13440.6
June 451.51 13545.3
July 470.37 14581.6
August 421.45 13064.8
September 339.58 10187.3
October 229.91 7127.11
November 164.59 4937.56
December 134.18 4159.56
Total yearly 118249

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 229.61 7118.03
February 290.54 8135.03
March 365.89 11342.5
April 416.73 12501.8
May 432.67 13412.8
June 447.65 13429.6
July 468.32 14518
August 424.75 13167.4
September 349.62 10488.6
October 242.72 7524.21
November 179.9 5396.95
December 150.16 4655
Total yearly 121690

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 250.8 7774.93
February 308.3 8632.36
March 377.55 11704
April 420.59 12617.8
May 429.93 13327.9
June 442.32 13269.5
July 464.1 14387.1
August 425.89 13202.6
September 357.58 10727.3
October 253.9 7870.86
November 193.72 5811.72
December 164.75 5107.13
Total yearly 124433

Daaquam Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 269.84 8365.14
February 323.84 9067.55
March 386.91 11994.3
April 422.08 12662.4
May 425.19 13180.8
June 434.65 13039.5
July 457.44 14180.5
August 424.83 13169.7
September 363.42 10902.5
October 263.42 8165.93
November 206.03 6180.8
December 177.89 5514.59
Total yearly 126424

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.88% angle of incidence loss and -2.35% temperature and irradiance loss. This totals to about -14.64%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

BrownleeKillalyLebretMendhamAtwaterBuena VistaFindlaterLancerBangorSiltonWaldronDuffAylesburyMarkinchBulyeaFenwoodMacNuttHubbardLibertyLerossStrongfieldBladworthQuintonHawardenGlensideMurdochville