The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Brownlee
  • GPS Coordinates: 50.73634, -106.020994
  • Elevation: 623 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Brownlee: 43o
  • Average yearly irradiance: 1533.28 kWh/m2
  • Average yearly power output: 130199 kWh
Sun Path Brownlee

Average yearly irradiance delivered by the Sun in Brownlee is 1533.28/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 130199 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.93 59.89
February 2.72 76.27
March 3.66 113.48
April 5.38 161.36
May 5.72 177.46
June 5.7 171.15
July 6.57 203.59
August 5.9 182.76
September 5.03 150.76
October 3.77 116.72
November 2.26 67.91
December 1.68 51.95
Total yearly 1533.28

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 184.35 5714.96
February 257.25 7203.03
March 328.1 10171.1
April 462.95 13888.4
May 477.62 14806.2
June 462.4 13872
July 525.3 16284.3
August 473.55 14680
September 415.78 12473.5
October 325.19 10081
November 203.98 6119.46
December 158.24 4905.33
Total yearly 130199

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Brownlee solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 115.07 3567.15
February 183.12 5127.23
March 275.49 8540.23
April 439.01 13170.4
May 496.37 15387.5
June 500.62 15018.7
July 557.94 17296.3
August 467.68 14498.1
September 364.75 10942.4
October 249.71 7740.92
November 136.03 4081.01
December 93.29 2891.87
Total yearly 118262

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 130.85 4056.31
February 200.77 5621.64
March 289.64 8978.71
April 449 13469.8
May 498.55 15455
June 498.99 14969.8
July 558.46 17312.1
August 474.74 14716.8
September 379.6 11387.8
October 268.2 8314.21
November 151.59 4547.62
December 107.88 3344.36
Total yearly 122174

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 145.29 4504
February 216.7 6067.59
March 301.8 9355.89
April 456.4 13691.9
May 497.87 15434.1
June 494.99 14849.8
July 556.4 17248.4
August 479.07 14851.1
September 392 11760.1
October 284.69 8825.28
November 165.77 4973.03
December 121.29 3759.84
Total yearly 125321

Brownlee Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 158.36 4909.26
February 230.86 6464.2
March 311.97 9670.95
April 461.19 13835.7
May 494.6 15332.5
June 488.09 14642.7
July 550.97 17080
August 480.73 14902.5
September 401.93 12057.8
October 299.12 9272.64
November 178.53 5356
December 133.46 4137.23
Total yearly 127661

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.69% angle of incidence loss and -3.05% temperature and irradiance loss. This totals to about -15.08%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.