Solar Calculator Canada

Solar Power Calculator for Donnacona, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Donnacona
  • GPS Coordinates: 46.6747222, -71.7294444
  • Elevation: 32 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Donnacona: 39o
  • Average yearly irradiance: 1467.06 kWh/m2
  • Average yearly power output: 123189 kWh
Sun Path Donnacona

Average yearly irradiance delivered by the Sun in Donnacona is 1467.06/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 123189 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.6 80.47
February 3.11 87.11
March 4.22 130.71
April 4.78 143.32
May 5.36 166.21
June 5.39 161.7
July 5.68 175.97
August 5.23 162.27
September 4.45 133.36
October 3.15 97.71
November 2.38 71.53
December 1.83 56.69
Total yearly 1467.06

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 244.15 7568.78
February 287.78 8057.77
March 375.56 11642.2
April 405.95 12178.5
May 438.18 13583.5
June 429.54 12886.3
July 447.89 13884.7
August 416.06 12898
September 359.91 10797.2
October 266.34 8256.65
November 208.62 6258.48
December 167.01 5177.21
Total yearly 123189

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Donnacona solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 171.41 5313.86
February 227.92 6381.76
March 332.27 10300.4
April 398.07 11942.2
May 459.5 14244.6
June 464.52 13935.7
July 477.63 14806.4
August 419.32 12999
September 331.36 9940.77
October 222.03 6882.88
November 154.55 4636.6
December 113.66 3523.36
Total yearly 114908

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 189.76 5882.45
February 243.77 6825.58
March 345.4 10707.4
April 403.79 12113.7
May 459.38 14240.8
June 461.18 13835.3
July 475.97 14755.2
August 422.84 13108
September 341.29 10238.8
October 234.23 7261.03
November 168.41 5052.22
December 126.99 3936.8
Total yearly 117957

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 206.4 6398.39
February 257.81 7218.79
March 356.37 11047.6
April 407.35 12220.5
May 456.95 14165.6
June 456.1 13682.9
July 471.77 14624.9
August 424.17 13149.3
September 349.19 10475.8
October 244.87 7591.09
November 180.89 5426.65
December 139.15 4313.76
Total yearly 120315

Donnacona Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 221.31 6860.5
February 270.02 7560.67
March 365.17 11320.2
April 408.83 12264.8
May 452.22 14018.8
June 448.53 13455.9
July 465.23 14422.1
August 423.33 13123.4
September 355.04 10651.3
October 253.93 7871.97
November 191.97 5759.04
December 150.1 4653.12
Total yearly 121962

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.83% angle of incidence loss and -3.98% temperature and irradiance loss. This totals to about -16.03%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.