Solar Calculator Canada

Solar Power Calculator for Douglastown, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Douglastown
  • GPS Coordinates: 48.766, -64.383
  • Elevation: 48 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Douglastown: 42o
  • Average yearly irradiance: 1469.22 kWh/m2
  • Average yearly power output: 126354 kWh
Sun Path Douglastown

Average yearly irradiance delivered by the Sun in Douglastown is 1469.22/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 126354 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.64 81.72
February 3.4 95.14
March 4.48 138.74
April 4.99 149.56
May 5.18 160.66
June 5.23 157.03
July 5.24 162.59
August 5.02 155.64
September 4.54 136.32
October 3.4 105.34
November 2.3 68.85
December 1.86 57.65
Total yearly 1469.22

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 250.9 7777.94
February 318.48 8917.51
March 408.19 12654
April 437.1 13112.9
May 437.58 13564.9
June 429.43 12882.9
July 420.81 13045
August 405.52 12571
September 376.89 11306.7
October 292.81 9077.07
November 203.73 6112
December 172.01 5332.34
Total yearly 126354

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Douglastown solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 167.88 5204.42
February 240.24 6726.85
March 351.45 10894.8
April 423.89 12716.7
May 461.6 14309.6
June 468.79 14063.5
July 451.51 13996.7
August 408.18 12653.7
September 339.11 10173.4
October 234.4 7266.25
November 144.38 4331.55
December 111.77 3464.96
Total yearly 115802

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 187.18 5802.6
February 259.24 7258.78
March 367.25 11384.7
April 431.67 12950.2
May 462.17 14327.3
June 465.9 13977.1
July 450.09 13952.8
August 412.46 12786.2
September 350.99 10529.7
October 249.16 7723.9
November 158.38 4751.45
December 125.64 3894.97
Total yearly 119340

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 204.75 6347.24
February 276.24 7734.73
March 380.69 11801.4
April 437.07 13112.2
May 460.51 14275.9
June 461.09 13832.8
July 446.73 13848.5
August 414.61 12853
September 360.7 10821.1
October 262.18 8127.53
November 171.06 5131.75
December 138.33 4288.21
Total yearly 122174

Douglastown Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 220.56 6837.25
February 291.2 8153.63
March 391.73 12143.7
April 440.06 13201.8
May 456.39 14148.1
June 454.41 13632.4
July 441.65 13691.2
August 414.61 12852.8
September 368.2 11045.9
October 273.42 8475.9
November 182.38 5471.47
December 149.8 4643.66
Total yearly 124298

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.76% angle of incidence loss and -1.73% temperature and irradiance loss. This totals to about -14%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: