Solar Calculator Canada

Solar Power Calculator for Dundee, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Dundee
  • GPS Coordinates: 45.001938, -74.507825
  • Elevation: 47 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Dundee: 38o
  • Average yearly irradiance: 1543.2 kWh/m2
  • Average yearly power output: 128724 kWh
Sun Path Dundee

Average yearly irradiance delivered by the Sun in Dundee is 1543.2/kWh/m2 at the optimal panel slope of 38o. After taking all losses into account, you can expect about 128724 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 38o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.63 81.59
February 3.34 93.43
March 4.4 136.3
April 5 150.04
May 5.55 172.02
June 5.45 163.38
July 5.87 181.87
August 5.68 176.01
September 4.83 144.76
October 3.37 104.61
November 2.74 82.09
December 1.84 57.1
Total yearly 1543.2

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 244.01 7564.28
February 306.19 8573.32
March 388.76 12051.4
April 421.09 12632.7
May 450.53 13966.4
June 432.44 12973.2
July 461.34 14301.6
August 450.03 13951
September 388.7 11661.1
October 282.79 8766.41
November 238.22 7146.48
December 165.69 5136.34
Total yearly 128724

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Dundee solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 178.04 5519.11
February 247.09 6918.57
March 347.63 10776.6
April 414.31 12429.4
May 473.2 14669.2
June 467.83 14034.9
July 493.05 15284.6
August 454.41 14086.7
September 360.33 10809.8
October 239.16 7413.89
November 180.99 5429.68
December 119.79 3713.44
Total yearly 121086

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 195.48 6059.85
February 263.48 7377.38
March 360.61 11179
April 419.76 12592.8
May 472.36 14643.3
June 464.03 13921
July 490.43 15203.5
August 457.75 14190.3
September 370.54 11116.1
October 251.69 7802.52
November 196.3 5889.01
December 131.84 4087.15
Total yearly 124062

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 211.27 6549.27
February 277.95 7782.57
March 371.37 11512.5
April 422.96 12688.8
May 469.17 14544.3
June 458 13740
July 485.38 15046.7
August 458.69 14219.4
September 378.55 11356.4
October 262.57 8139.82
November 210.06 6301.68
December 142.77 4425.8
Total yearly 126307

Dundee Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 225.36 6986.02
February 290.48 8133.38
March 379.88 11776.4
April 423.9 12717
May 463.65 14373.2
June 449.77 13493.2
July 477.92 14815.5
August 457.22 14173.9
September 384.33 11530
October 271.77 8424.74
November 222.22 6666.74
December 152.53 4728.54
Total yearly 127819

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.8% angle of incidence loss and -4.64% temperature and irradiance loss. This totals to about -16.59%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: