Solar Calculator Canada

Solar Power Calculator for Ham-Nord, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Ham-Nord
  • GPS Coordinates: 45.9, -71.65
  • Elevation: 283 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Ham-Nord: 38o
  • Average yearly irradiance: 1430.01 kWh/m2
  • Average yearly power output: 120594 kWh
Sun Path Ham-Nord

Average yearly irradiance delivered by the Sun in Ham-Nord is 1430.01/kWh/m2 at the optimal panel slope of 38o. After taking all losses into account, you can expect about 120594 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 38o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.6 80.62
February 3.06 85.64
March 4.14 128.41
April 4.65 139.47
May 5.12 158.67
June 5.2 156.05
July 5.53 171.31
August 5.16 159.87
September 4.36 130.81
October 3.08 95.41
November 2.39 71.67
December 1.68 52.07
Total yearly 1430.01

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 245.18 7600.54
February 283.74 7944.79
March 370 11469.9
April 395.83 11874.9
May 420.52 13036.1
June 417.99 12539.7
July 439.41 13621.7
August 412.96 12801.7
September 354.69 10640.7
October 259.99 8059.74
November 209.09 6272.8
December 152.63 4731.61
Total yearly 120594

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Ham-Nord solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 176.27 5464.34
February 229.42 6423.83
March 330.58 10247.9
April 389.6 11688
May 441.12 13674.6
June 451.7 13550.9
July 468.74 14531
August 417.19 12932.8
September 329.34 9880.07
October 219.32 6798.98
November 157.31 4719.17
December 108.03 3348.95
Total yearly 113261

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 194.29 6022.89
February 244.36 6842.19
March 343.01 10633.3
April 394.68 11840.5
May 440.42 13653.1
June 447.85 13435.4
July 466.49 14461.2
August 420.14 13024.2
September 338.51 10155.2
October 230.92 7158.67
November 171.04 5131.34
December 119.61 3707.96
Total yearly 116066

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 210.62 6529.33
February 257.56 7211.77
March 353.33 10953.2
April 397.67 11930.2
May 437.52 13563.2
June 442.31 13269.2
July 461.8 14315.7
August 420.93 13048.7
September 345.69 10370.7
October 241.01 7471.3
November 183.4 5502.02
December 130.15 4034.6
Total yearly 118200

Ham-Nord Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 225.23 6982.28
February 268.99 7531.69
March 361.51 11206.9
April 398.71 11961.3
May 432.5 13407.4
June 434.43 13032.9
July 454.85 14100.3
August 419.59 13007.4
September 350.86 10525.9
October 249.54 7735.84
November 194.35 5830.35
December 139.6 4327.68
Total yearly 119650

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.92% angle of incidence loss and -3.48% temperature and irradiance loss. This totals to about -15.67%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Lac-BromeSaint-R�miWatervilleFarnhamBeauharnoisBromontWaterlooCh�teauguayVaudreuil-DorionSaint-C�saireCookshire-EatonLa PrairieMarievilleChamblyHudsonRigaudEast AngusClarence-RocklandSaint-PieValcourtLongueuilScotstownLavalSaint-EustacheWindsorMurdochville