Solar Calculator Canada

Solar Power Calculator for Joly, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Joly
  • GPS Coordinates: 46.4852778, -71.6683333
  • Elevation: 115 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Joly: 40o
  • Average yearly irradiance: 1518.1 kWh/m2
  • Average yearly power output: 128067 kWh
Sun Path Joly

Average yearly irradiance delivered by the Sun in Joly is 1518.1/kWh/m2 at the optimal panel slope of 40o. After taking all losses into account, you can expect about 128067 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 40o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.96 91.86
February 3.64 101.86
March 4.53 140.4
April 4.84 145.14
May 5.25 162.86
June 5.36 160.91
July 5.62 174.18
August 5.31 164.67
September 4.55 136.39
October 3.23 100.25
November 2.55 76.63
December 2.03 62.96
Total yearly 1518.1

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 280.38 8691.69
February 338.74 9484.8
March 404.42 12537.1
April 410.11 12303.4
May 429.28 13307.8
June 428.21 12846.2
July 443.89 13760.5
August 422.87 13109.1
September 368.39 11051.7
October 273.25 8470.84
November 224.01 6720.45
December 186.56 5783.51
Total yearly 128067

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Joly solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 193.89 6010.66
February 264.17 7396.79
March 356.06 11037.9
April 403 12090
May 453.07 14045.1
June 466.45 13993.4
July 476.88 14783.4
August 428.01 13268.3
September 339.14 10174.2
October 226.8 7030.84
November 164.35 4930.64
December 125.9 3902.84
Total yearly 118664

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 215.03 6665.82
February 283.28 7931.94
March 370.43 11483.4
April 408.8 12263.9
May 452.76 14035.6
June 462.9 13887
July 475.03 14725.8
August 431.49 13376.2
September 349.26 10477.7
October 239.31 7418.66
November 179.23 5376.9
December 140.6 4358.68
Total yearly 122002

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 234.24 7261.44
February 300.28 8407.86
March 382.49 11857.2
April 412.4 12372
May 450.19 13956
June 457.65 13729.5
July 470.62 14589.2
August 432.72 13414.5
September 357.3 10718.9
October 250.23 7756.99
November 192.63 5778.93
December 154.02 4774.56
Total yearly 124617

Joly Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 251.48 7795.97
February 315.13 8823.52
March 392.2 12158.3
April 413.92 12417.7
May 445.36 13806.1
June 449.91 13497.2
July 463.88 14380.4
August 431.74 13383.8
September 363.21 10896.4
October 259.51 8044.75
November 204.53 6135.89
December 166.1 5149.15
Total yearly 126489

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.81% angle of incidence loss and -3.56% temperature and irradiance loss. This totals to about -15.64%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Murdochville