Solar Calculator Canada

Solar Power Calculator for Macamic, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Macamic
  • GPS Coordinates: 48.75, -79
  • Elevation: 285 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Macamic: 40o
  • Average yearly irradiance: 1417.06 kWh/m2
  • Average yearly power output: 120609 kWh
Sun Path Macamic

Average yearly irradiance delivered by the Sun in Macamic is 1417.06/kWh/m2 at the optimal panel slope of 40o. After taking all losses into account, you can expect about 120609 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 40o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.36 73.08
February 3.27 91.42
March 4.29 133.08
April 4.6 137.95
May 5.48 169.78
June 5.66 169.84
July 5.43 168.19
August 5.11 158.56
September 4.24 127.24
October 2.83 87.81
November 1.84 55.15
December 1.45 44.95
Total yearly 1417.06

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 227.53 7053.31
February 309.91 8677.6
March 389.7 12080.8
April 396.49 11894.7
May 453.42 14055.9
June 455.52 13665.7
July 433.23 13430.1
August 411.98 12771.5
September 348.77 10463.2
October 241.18 7476.73
November 161.75 4852.43
December 135.08 4187.38
Total yearly 120609

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Macamic solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 154.58 4791.83
February 237.5 6649.93
March 337.92 10475.4
April 387.02 11610.7
May 472.68 14653.2
June 490.81 14724.4
July 460.7 14281.7
August 412.12 12775.8
September 317.13 9513.8
October 199.43 6182.37
November 118.41 3552.33
December 91.29 2830.12
Total yearly 112042

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 172.45 5346
February 256.06 7169.61
March 352.9 10939.8
April 393.14 11794.3
May 473.55 14680.1
June 487.97 14639.1
July 459.21 14235.4
August 416.45 12910
September 327.42 9822.47
October 210.63 6529.58
November 129.2 3876.04
December 102.05 3163.4
Total yearly 115106

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 188.69 5849.53
February 272.62 7633.26
March 365.6 11333.5
April 397.17 11915.1
May 472.05 14633.5
June 483.2 14496.1
July 455.76 14128.6
August 418.62 12977.3
September 335.76 10072.7
October 220.43 6833.2
November 138.96 4168.83
December 111.82 3466.47
Total yearly 117508

Macamic Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 203.28 6301.56
February 287.15 8040.16
March 375.99 11655.7
April 399.1 11973.1
May 468.05 14509.6
June 476.26 14287.9
July 450.48 13964.9
August 418.68 12979
September 342.08 10262.4
October 228.78 7092.25
November 147.65 4429.6
December 120.6 3738.75
Total yearly 119235

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.84% angle of incidence loss and -2.67% temperature and irradiance loss. This totals to about -14.89%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Nipissing OuestWest NipissingFlorenceville-BristolNorth RusticoMarkstay-WarrenLaurier-StationRichibuctoPortugal Cove SouthO'LearySt. Vincent's-St. Stephen's-Peter's RiverAlbertonSainte-P�tronilleBranchLord's CoveLamalineSt. LawrenceSt. Mary'sSt. Bride'sLawnPoint MayFermeuseRiverheadAdmirals BeachFortuneTemagamiMurdochville