Solar Calculator Canada

Solar Power Calculator for Maniwaki, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Maniwaki
  • GPS Coordinates: 46.374513, -75.981891
  • Elevation: 183 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Maniwaki: 39o
  • Average yearly irradiance: 1525.03 kWh/m2
  • Average yearly power output: 128773 kWh
Sun Path Maniwaki

Average yearly irradiance delivered by the Sun in Maniwaki is 1525.03/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 128773 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.81 87.07
February 3.65 102.22
March 4.74 146.96
April 4.92 147.57
May 5.38 166.85
June 5.42 162.45
July 5.62 174.24
August 5.44 168.62
September 4.56 136.68
October 3.19 98.78
November 2.49 74.7
December 1.9 58.88
Total yearly 1525.03

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 266.16 8250.92
February 341.49 9561.62
March 427.13 13240.9
April 420.13 12604
May 439.23 13616.3
June 431.53 12946
July 443.59 13751.4
August 433.51 13438.7
September 370.05 11101.6
October 268.82 8333.56
November 218.1 6543.07
December 173.71 5385.02
Total yearly 128773

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Maniwaki solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 188.38 5839.91
February 268.74 7524.59
March 375.72 11647.2
April 412.33 12370
May 463.26 14361.1
June 470.18 14105.3
July 476.99 14786.6
August 438.19 13583.9
September 340.95 10228.4
October 225.35 6985.89
November 161.97 4858.95
December 121.76 3774.67
Total yearly 120067

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 208.01 6448.27
February 287.79 8058.24
March 391.01 12121.4
April 418.28 12548.5
May 462.76 14345.4
June 466.79 14003.7
July 474.84 14719.9
August 441.72 13693.2
September 351.04 10531.2
October 237.35 7357.79
November 176.24 5287.05
December 134.78 4178.33
Total yearly 123293

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 225.77 6998.78
February 304.73 8532.43
March 403.86 12519.7
April 421.98 12659.5
May 459.93 14257.8
June 460.86 13825.7
July 470.07 14572.3
August 442.93 13730.9
September 359.05 10771.6
October 247.79 7681.38
November 189.09 5672.71
December 146.58 4543.83
Total yearly 125767

Maniwaki Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 241.63 7490.61
February 319.5 8946.12
March 414.23 12841
April 423.43 12702.9
May 454.82 14099.3
June 452.71 13581.2
July 463.01 14353.4
August 441.84 13697
September 364.95 10948.6
October 256.63 7955.6
November 200.5 6014.91
December 157.12 4870.75
Total yearly 127501

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.82% angle of incidence loss and -3.46% temperature and irradiance loss. This totals to about -15.56%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

HawkesburyPort HawkesburyAntigonishSussexAmherstOromoctoFort-CoulongeGore BaySackvilleDeep RiverWoodstockMontagueShediacEspanolaThessalonMattawaSourisBouctoucheTrepasseyFerrylandGrand FallsGrand-SaultBurinGrand BankMarystownMurdochville