Solar Calculator Canada

Solar Power Calculator for Mingan, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Mingan
  • GPS Coordinates: 50.291111, -64.019167
  • Elevation: 1 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Mingan: 38o
  • Average yearly irradiance: 1299.14 kWh/m2
  • Average yearly power output: 111774 kWh
Sun Path Mingan

Average yearly irradiance delivered by the Sun in Mingan is 1299.14/kWh/m2 at the optimal panel slope of 38o. After taking all losses into account, you can expect about 111774 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 38o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.4 43.27
February 2.33 65.12
March 3.43 106.28
April 4.67 140.14
May 5.22 161.73
June 5.31 159.2
July 5.3 164.26
August 4.88 151.13
September 4 120.14
October 2.95 91.52
November 1.84 55.26
December 1.33 41.08
Total yearly 1299.14

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 120.3 3729.37
February 202.18 5660.93
March 296.04 9177.27
April 399.55 11986.6
May 445.66 13815.4
June 454.1 13623.1
July 454.82 14099.4
August 419.41 13001.8
September 345.95 10378.5
October 256.49 7951.16
November 159.97 4799.03
December 114.58 3551.87
Total yearly 111774

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Mingan solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 89.4 2771.31
February 164.03 4592.83
March 265.5 8230.44
April 386.53 11595.8
May 458.81 14223
June 480.65 14419.4
July 474.3 14703.2
August 415.86 12891.6
September 315.05 9451.61
October 210.47 6524.56
November 117.74 3532.35
December 79.49 2464.14
Total yearly 105400

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 97.56 3024.27
February 174.54 4887.12
March 275.03 8525.98
April 393.04 11791.1
May 459.87 14255.8
June 478.39 14351.6
July 473.52 14679.2
August 420.37 13031.6
September 325.19 9755.73
October 223.28 6921.82
November 128.91 3867.16
December 88.62 2747.32
Total yearly 107839

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 104.94 3253.29
February 183.85 5147.82
March 282.98 8772.53
April 397.5 11925
May 458.82 14223.6
June 474.19 14225.7
July 470.76 14593.5
August 422.84 13108
September 333.46 10003.7
October 234.56 7271.38
November 138.99 4169.67
December 96.94 3005.26
Total yearly 109699

Mingan Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 111.54 3457.71
February 191.94 5374.34
March 289.34 8969.45
April 399.93 11997.9
May 455.44 14118.6
June 468.33 14050
July 466.37 14457.5
August 423.2 13119.1
September 339.81 10194.2
October 244.27 7572.51
November 147.98 4439.3
December 104.43 3237.37
Total yearly 110988

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.94% angle of incidence loss and -1.51% temperature and irradiance loss. This totals to about -13.96%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: