Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Nicolet: 39o
  • Average yearly irradiance: 1509.27 kWh/m2
  • Average yearly power output: 127419 kWh
Sun Path Nicolet

Average yearly irradiance delivered by the Sun in Nicolet is 1509.27/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 127419 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.68 83.2
February 3.18 89.14
March 4.22 130.84
April 4.91 147.41
May 5.46 169.12
June 5.49 164.57
July 5.81 180.24
August 5.45 168.86
September 4.65 139.47
October 3.27 101.5
November 2.59 77.81
December 1.84 57.1
Total yearly 1509.27

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 253.04 7844.11
February 295.33 8269.2
March 377.79 11711.5
April 420.83 12624.9
May 448.9 13916
June 439.36 13180.9
July 461.09 14293.8
August 435.68 13506.1
September 379.1 11372.9
October 278.25 8625.81
November 228.63 6858.96
December 168.21 5214.65
Total yearly 127419

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Nicolet solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 176.81 5481.05
February 232.7 6515.52
March 334.27 10362.4
April 412.05 12361.4
May 470.78 14594.1
June 475.88 14276.3
July 492.36 15263.2
August 439.31 13618.7
September 349.04 10471.2
October 232.26 7200.03
November 169.19 5075.69
December 115.44 3578.5
Total yearly 118798

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 196.04 6077.33
February 249.32 6981.07
March 347.52 10773
April 418.17 12545
May 470.74 14593.1
June 472.73 14181.8
July 490.63 15209.5
August 443.01 13733.2
September 359.45 10783.5
October 244.93 7592.86
November 184.42 5532.51
December 128.64 3987.76
Total yearly 121991

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 213.51 6618.87
February 264.06 7393.78
March 358.58 11115.9
April 422.02 12660.5
May 468.22 14514.8
June 467.06 14011.9
July 486.31 15075.5
August 444.38 13775.8
September 367.71 11031.4
October 255.99 7935.58
November 198.14 5944.08
December 140.66 4360.47
Total yearly 124439

Nicolet Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 229.17 7104.27
February 276.89 7752.99
March 367.42 11390
April 423.58 12707.5
May 463.34 14363.6
June 459.13 13774
July 479.54 14865.7
August 443.43 13746.4
September 373.82 11214.5
October 265.39 8226.94
November 210.32 6309.51
December 151.47 4695.59
Total yearly 126151

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.78% angle of incidence loss and -3.52% temperature and irradiance loss. This totals to about -15.58%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

MulgraveKearneyGrenvillePictouOxfordNortheastern Manitoulin and the IslandsMassuevilleLa GuadeloupeLaurentian HillsNackawicNotre-Dame-du-Bon-ConseilVal-DavidRiverviewFrench RiverRivi�re des Fran�aisGeorgetownSaint-C�lestinStratfordCornwallBorden-CarletonTring-JonctionHartlandBruce MinesSt.-CharlesKensingtonMurdochville