Solar Calculator Canada

Solar Power Calculator for Riverview, New Brunswick, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Riverview
  • GPS Coordinates: 46.054444, -64.817222
  • Elevation: 36 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Riverview: 40o
  • Average yearly irradiance: 1504.66 kWh/m2
  • Average yearly power output: 127185 kWh
Sun Path Riverview

Average yearly irradiance delivered by the Sun in Riverview is 1504.66/kWh/m2 at the optimal panel slope of 40o. After taking all losses into account, you can expect about 127185 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 40o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.87 89.04
February 3.53 98.82
March 4.34 134.59
April 4.75 142.57
May 4.92 152.49
June 4.93 147.97
July 5.41 167.57
August 5.27 163.38
September 4.78 143.33
October 3.74 115.81
November 2.68 80.52
December 2.21 68.58
Total yearly 1504.66

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 268.42 8321.16
February 323.45 9056.67
March 386.14 11970.3
April 405.49 12164.8
May 406.59 12604.4
June 397.59 11927.6
July 428.9 13295.8
August 419.81 13014
September 390.11 11703.4
October 316.65 9816.1
November 235.69 7070.8
December 201.29 6240.1
Total yearly 127185

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Riverview solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 186.53 5782.5
February 250.18 7005.13
March 341.71 10593
April 400.61 12018.4
May 432.76 13415.6
June 435.57 13067
July 461.8 14315.8
August 425.97 13205.2
September 357.68 10730.5
October 258.91 8026.14
November 170.88 5126.33
December 135.38 4196.66
Total yearly 117482

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 206.54 6402.84
February 268.79 7526.14
March 354.95 11003.4
April 406.1 12182.9
May 431.91 13389.2
June 431.77 12953.1
July 459.47 14243.4
August 429.45 13313
September 368.68 11060.4
October 274.17 8499.2
November 186.8 5603.93
December 151.27 4689.44
Total yearly 120867

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 224.67 6964.75
February 285.36 7990.05
March 365.98 11345.4
April 409.41 12282.4
May 428.93 13296.7
June 426.54 12796.1
July 455.3 14114.3
August 430.77 13353.8
September 377.44 11323.2
October 287.52 8913.18
November 201.19 6035.78
December 165.76 5138.49
Total yearly 123554

Riverview Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 240.88 7467.37
February 299.85 8395.74
March 374.78 11618.1
April 410.51 12315.3
May 423.81 13138
June 419.21 12576.2
July 449.26 13927.2
August 429.7 13320.7
September 383.94 11518.2
October 298.93 9266.98
November 214.02 6420.51
December 178.8 5542.66
Total yearly 125507

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.8% angle of incidence loss and -3.38% temperature and irradiance loss. This totals to about -15.47%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.