Solar Calculator Canada

Solar Power Calculator for Normandin, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Normandin
  • GPS Coordinates: 48.8333334, -72.5333333
  • Elevation: 142 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Normandin: 40o
  • Average yearly irradiance: 1388.93 kWh/m2
  • Average yearly power output: 117842 kWh
Sun Path Normandin

Average yearly irradiance delivered by the Sun in Normandin is 1388.93/kWh/m2 at the optimal panel slope of 40o. After taking all losses into account, you can expect about 117842 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 40o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.28 70.67
February 3.15 88.08
March 4.14 128.41
April 4.55 136.55
May 5.46 169.36
June 5.44 163.27
July 5.24 162.41
August 4.87 151.07
September 4.15 124.55
October 2.83 87.66
November 1.85 55.53
December 1.66 51.35
Total yearly 1388.93

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 218.23 6764.99
February 296.19 8293.45
March 374.32 11603.9
April 392.71 11781.4
May 451.24 13988.4
June 436.54 13096.1
July 415.87 12892
August 390.3 12099.4
September 339.99 10199.7
October 240.5 7455.65
November 163.3 4899.13
December 153.79 4767.51
Total yearly 117842

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Normandin solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 148.15 4592.56
February 225.87 6324.44
March 323.54 10029.8
April 383.42 11502.5
May 470.82 14595.5
June 471.14 14134.2
July 443.7 13754.6
August 392.78 12176.3
September 310.54 9316.33
October 199.14 6173.32
November 119.89 3596.67
December 100.9 3127.98
Total yearly 109324

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 165.21 5121.63
February 243.72 6824.15
March 338.09 10480.8
April 389.41 11682.2
May 471.61 14620
June 468.59 14057.6
July 442.65 13722.1
August 396.4 12288.5
September 320.33 9610.04
October 210.2 6516.24
November 130.64 3919.34
December 113.69 3524.45
Total yearly 112367

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 180.73 5602.7
February 259.65 7270.09
March 350.44 10863.5
April 393.33 11800
May 470.11 14573.5
June 464.25 13927.4
July 439.26 13617
August 397.97 12337.1
September 328.22 9846.72
October 219.89 6816.47
November 140.36 4210.95
December 125.36 3886.29
Total yearly 114752

Normandin Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 194.67 6034.84
February 273.63 7661.59
March 360.56 11177.3
April 395.17 11855.2
May 466.13 14450
June 457.31 13719.2
July 433.69 13444.5
August 397.49 12322.2
September 334.19 10025.7
October 228.16 7072.92
November 149.02 4470.54
December 135.89 4212.61
Total yearly 116447

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.86% angle of incidence loss and -2.96% temperature and irradiance loss. This totals to about -15.16%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Nipissing OuestWest NipissingFlorenceville-BristolNorth RusticoMarkstay-WarrenLaurier-StationRichibuctoPortugal Cove SouthO'LearySt. Vincent's-St. Stephen's-Peter's RiverAlbertonSainte-P�tronilleBranchLord's CoveLamalineSt. LawrenceSt. Mary'sSt. Bride'sLawnPoint MayFermeuseRiverheadAdmirals BeachFortuneTemagamiMurdochville