Solar Calculator Canada

Solar Power Calculator for Notre-Dame-de-Pierreville, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Notre-Dame-de-Pierreville
  • GPS Coordinates: 46.1041667, -72.8805556
  • Elevation: 2 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Notre-Dame-de-Pierreville: 39o
  • Average yearly irradiance: 1538.78 kWh/m2
  • Average yearly power output: 129628 kWh
Sun Path Notre-Dame-de-Pierreville

Average yearly irradiance delivered by the Sun in Notre-Dame-de-Pierreville is 1538.78/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 129628 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.72 84.45
February 3.15 88.3
March 4.29 132.89
April 5.03 150.87
May 5.54 171.67
June 5.6 167.9
July 5.86 181.66
August 5.53 171.51
September 4.72 141.6
October 3.42 106.06
November 2.75 82.4
December 1.92 59.47
Total yearly 1538.78

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 255.65 7925.08
February 291.36 8158.02
March 382.4 11854.3
April 429.45 12883.4
May 454.28 14082.7
June 447.36 13420.7
July 463.93 14381.8
August 441.53 13687.5
September 383.98 11519.4
October 290.63 9009.53
November 242.55 7276.63
December 175.12 5428.87
Total yearly 129628

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Notre-Dame-de-Pierreville solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 178.63 5537.5
February 229.03 6412.88
March 337.52 10463.2
April 420.29 12608.6
May 476.84 14782
June 484.96 14548.7
July 496.08 15378.5
August 444.59 13782.3
September 353.48 10604.3
October 241.57 7488.72
November 178.66 5359.92
December 120.17 3725.16
Total yearly 120692

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 198.03 6138.9
February 245.51 6874.3
March 351.07 10883.1
April 426.57 12797
May 476.78 14780.3
June 481.77 14453.2
July 494.2 15320.3
August 448.5 13903.5
September 364.05 10921.6
October 255.01 7905.16
November 194.93 5847.78
December 133.87 4150.04
Total yearly 123975

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 215.63 6684.64
February 260.12 7283.37
March 362.39 11234.2
April 430.53 12915.9
May 474.22 14700.7
June 475.99 14279.8
July 489.75 15182.1
August 450.05 13951.5
September 372.46 11173.7
October 266.74 8268.79
November 209.59 6287.56
December 146.35 4536.83
Total yearly 126499

Notre-Dame-de-Pierreville Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 231.4 7173.48
February 272.84 7639.49
March 371.47 11515.6
April 432.16 12964.7
May 469.26 14547.1
June 467.89 14036.7
July 482.84 14967.9
August 449.23 13926.1
September 378.67 11360
October 276.72 8578.38
November 222.61 6678.3
December 157.57 4884.53
Total yearly 128272

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.76% angle of incidence loss and -3.75% temperature and irradiance loss. This totals to about -15.76%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

South RiverNorth RiverNorman's Cove-Long CoveLittle Bay EastBurnt IslandsLogy Bay-Middle Cove-Outer CoveUpper Island CovePool's CoveWhitewayBaulineHeart's Delight-IslingtonSalmon CoveHeart's DesireSmall Point-Adam's Cove-Blackhead-Broad CoveMorrisvilleNew PerlicanSaint-Andr�-du-Lac-Saint-JeanTrinityH�bertville-StationView RoyalTerra NovaPort au Port EastDuntaraKeelsEllistonMurdochville