Solar Calculator Canada

Solar Power Calculator for Glenwood, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Glenwood
  • GPS Coordinates: 49.3644445, -113.5113889
  • Elevation: 1099 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Glenwood: 42o
  • Average yearly irradiance: 1637.27 kWh/m2
  • Average yearly power output: 137396 kWh
Sun Path Glenwood

Average yearly irradiance delivered by the Sun in Glenwood is 1637.27/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 137396 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.27 70.48
February 3.13 87.52
March 4.07 126.24
April 5.3 158.89
May 5.75 178.4
June 5.9 177.1
July 6.79 210.55
August 6.21 192.48
September 5.29 158.61
October 3.97 123.03
November 2.78 83.44
December 2.27 70.52
Total yearly 1637.27

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 206.22 6392.88
February 278.62 7801.46
March 356.19 11042
April 452.57 13577.2
May 476.53 14772.5
June 478.04 14341.3
July 537.69 16668.3
August 493.77 15306.9
September 432.83 12984.9
October 340.4 10552.4
November 249.3 7479.03
December 208.92 6476.51
Total yearly 137396

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Glenwood solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 133.93 4151.95
February 205.99 5767.64
March 305.16 9459.86
April 434.85 13045.4
May 497.12 15410.9
June 520.39 15611.6
July 573.59 17781.4
August 488.53 15144.4
September 383.94 11518.1
October 265.21 8221.47
November 169.16 5074.81
December 126.74 3928.98
Total yearly 125116

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 150.56 4667.24
February 223.47 6257.09
March 319.16 9893.89
April 443.69 13310.7
May 498.48 15452.9
June 517.35 15520.5
July 572.92 17760.5
August 495.59 15363.4
September 398.6 11957.9
October 283.79 8797.53
November 187.75 5632.47
December 145.41 4507.78
Total yearly 129122

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 165.73 5137.66
February 239.14 6695.98
March 331.11 10264.5
April 450.1 13503.1
May 497.53 15423.5
June 511.97 15359.2
July 569.71 17661
August 499.89 15496.7
September 410.73 12321.9
October 300.3 9309.31
November 204.66 6139.88
December 162.56 5039.43
Total yearly 132352

Glenwood Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 179.42 5562
February 252.98 7083.49
March 340.99 10570.6
April 453.88 13616.5
May 494.61 15333
June 504.71 15141.4
July 563.96 17482.8
August 501.39 15543.1
September 420.3 12609.1
October 314.69 9755.33
November 219.86 6595.72
December 178.13 5522.15
Total yearly 134815

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.67% angle of incidence loss and -4.2% temperature and irradiance loss. This totals to about -16.08%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: