Solar Calculator Canada

Solar Power Calculator for Warwick, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Warwick
  • GPS Coordinates: 45.95, -71.9833334
  • Elevation: 167 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Warwick: 38o
  • Average yearly irradiance: 1448.48 kWh/m2
  • Average yearly power output: 121318 kWh
Sun Path Warwick

Average yearly irradiance delivered by the Sun in Warwick is 1448.48/kWh/m2 at the optimal panel slope of 38o. After taking all losses into account, you can expect about 121318 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 38o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.57 79.69
February 2.97 83.27
March 4.07 126.29
April 4.76 142.78
May 5.19 160.79
June 5.27 157.95
July 5.63 174.51
August 5.27 163.48
September 4.47 133.96
October 3.18 98.63
November 2.44 73.15
December 1.74 53.97
Total yearly 1448.48

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 240.6 7458.66
February 273.44 7656.24
March 360.74 11182.9
April 402.16 12064.7
May 423.49 13128.2
June 420.35 12610.7
July 444.76 13787.6
August 419.79 13013.4
September 361.47 10844.2
October 267.82 8302.27
November 212.72 6381.72
December 157.67 4887.67
Total yearly 121318

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Warwick solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 172.13 5335.95
February 219.45 6144.61
March 321.92 9979.52
April 394.92 11847.6
May 443.98 13763.3
June 454.47 13634.2
July 474.17 14699.3
August 423.7 13134.7
September 334.96 10048.7
October 225.25 6982.86
November 159.53 4785.91
December 110.26 3418.1
Total yearly 113775

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 189.92 5887.6
February 234.17 6556.88
March 334.08 10356.5
April 400.32 12009.6
May 443.49 13748.2
June 450.84 13525.2
July 472.06 14634
August 426.88 13233.3
September 344.46 10333.7
October 237.28 7355.63
November 173.55 5206.5
December 122.51 3797.81
Total yearly 116645

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 206.05 6387.62
February 247.19 6921.21
March 344.18 10669.6
April 403.58 12107.5
May 440.7 13661.8
June 445.22 13356.5
July 467.49 14492.3
August 427.86 13263.5
September 351.93 10557.8
October 247.74 7679.9
November 186.16 5584.83
December 133.65 4143.14
Total yearly 118826

Warwick Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 220.48 6834.76
February 258.46 7236.92
March 352.19 10917.9
April 404.79 12143.6
May 435.77 13509
June 437.35 13120.6
July 460.63 14279.6
August 426.64 13225.9
September 357.35 10720.5
October 256.6 7954.62
November 197.34 5920.08
December 143.65 4453.1
Total yearly 120317

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.87% angle of incidence loss and -4.18% temperature and irradiance loss. This totals to about -16.24%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

MulgraveKearneyGrenvillePictouOxfordNortheastern Manitoulin and the IslandsMassuevilleLa GuadeloupeLaurentian HillsNackawicNotre-Dame-du-Bon-ConseilVal-DavidRiverviewFrench RiverRivi�re des Fran�aisGeorgetownSaint-C�lestinStratfordCornwallBorden-CarletonTring-JonctionHartlandBruce MinesSt.-CharlesKensingtonMurdochville