Solar Calculator Canada

Solar Power Calculator for Carlyle, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Carlyle
  • GPS Coordinates: 49.6353911, -102.2663556
  • Elevation: 632 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Carlyle: 42o
  • Average yearly irradiance: 1587.62 kWh/m2
  • Average yearly power output: 135408 kWh
Sun Path Carlyle

Average yearly irradiance delivered by the Sun in Carlyle is 1587.62/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 135408 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.2 68.06
February 3.02 84.51
March 3.8 117.72
April 5.49 164.71
May 5.69 176.53
June 5.77 173.06
July 6.5 201.4
August 6 186.12
September 5.29 158.65
October 3.88 120.22
November 2.61 78.41
December 1.88 58.21
Total yearly 1587.62

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 210.39 6522.1
February 285.34 7989.43
March 341.08 10573.6
April 473.87 14216
May 476.07 14758.3
June 467.98 14039.3
July 520.37 16131.4
August 483.43 14986.2
September 437.93 13138
October 336.2 10422.2
November 237.47 7124.13
December 177.65 5507.23
Total yearly 135408

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Carlyle solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 134.46 4168.41
February 206.64 5786
March 289.76 8982.68
April 454.84 13645.2
May 499.8 15493.7
June 511.62 15348.5
July 556.27 17244.5
August 480.36 14891.2
September 386.67 11600.2
October 260.96 8089.72
November 160.99 4829.79
December 107.91 3345.12
Total yearly 123425

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 151.75 4704.35
February 225.1 6302.82
March 303.67 9413.75
April 464.46 13933.8
May 501.1 15534
June 508.88 15266.3
July 556.22 17242.8
August 486.94 15095.2
September 401.92 12057.5
October 279.41 8661.56
November 178.67 5360.14
December 123.58 3831.01
Total yearly 127403

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 167.53 5193.29
February 241.66 6766.46
March 315.55 9781.93
April 471.42 14142.6
May 499.95 15498.4
June 504.11 15123.4
July 553.08 17145.6
August 490.8 15214.9
September 414.57 12437.2
October 295.81 9169.96
November 194.74 5842.12
December 137.95 4276.39
Total yearly 130592

Carlyle Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 181.76 5634.44
February 256.3 7176.26
March 325.36 10086.3
April 475.7 14270.9
May 496.06 15377.7
June 496.41 14892.4
July 546.86 16952.6
August 491.94 15250
September 424.62 12738.7
October 310.11 9613.28
November 209.15 6274.63
December 150.97 4680.07
Total yearly 132947

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.69% angle of incidence loss and -2.62% temperature and irradiance loss. This totals to about -14.71%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: