Solar Calculator Canada

Solar Power Calculator for Lloydminster, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Lloydminster
  • GPS Coordinates: 53.2838889, -110
  • Elevation: 645 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Lloydminster: 44o
  • Average yearly irradiance: 1467.82 kWh/m2
  • Average yearly power output: 125309 kWh
Sun Path Lloydminster

Average yearly irradiance delivered by the Sun in Lloydminster is 1467.82/kWh/m2 at the optimal panel slope of 44o. After taking all losses into account, you can expect about 125309 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 44o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.59 49.4
February 2.59 72.41
March 3.68 114.06
April 5.13 153.95
May 5.88 182.17
June 5.53 165.86
July 6.22 192.91
August 5.58 172.91
September 4.85 145.64
October 3.6 111.48
November 2.02 60.72
December 1.49 46.34
Total yearly 1467.82

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 152.5 4727.39
February 244.57 6847.86
March 333.31 10332.6
April 444.23 13326.8
May 490.71 15211.9
June 449.39 13481.7
July 500.84 15526
August 452.55 14028.9
September 404.74 12142.3
October 313.01 9703.39
November 185.08 5552.39
December 142.83 4427.84
Total yearly 125309

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Lloydminster solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 89.43 2772.48
February 168.02 4704.6
March 271.89 8428.66
April 417.99 12539.7
May 507.43 15730.5
June 486.08 14582.3
July 530.11 16433.3
August 443.17 13738.3
September 348.43 10452.8
October 229.92 7127.57
November 114.96 3448.92
December 78.82 2443.29
Total yearly 112402

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 102.96 3191.84
February 185.17 5184.62
March 287.49 8912.05
April 428.58 12857.5
May 510.66 15830.4
June 485 14549.9
July 531.16 16465.9
August 450.77 13973.9
September 363.86 10915.7
October 249 7718.93
November 130.12 3903.59
December 92.44 2865.7
Total yearly 116370

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 115.4 3577.33
February 200.69 5619.21
March 301.05 9332.6
April 436.65 13099.4
May 511.5 15856.4
June 481.63 14449
July 529.57 16416.6
August 455.98 14135.5
September 376.92 11307.7
October 266.13 8249.91
November 144.01 4320.31
December 105 3254.96
Total yearly 119619

Lloydminster Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 126.7 3927.79
February 214.55 6007.53
March 312.56 9689.38
April 442.21 13266.2
May 509.73 15801.7
June 476.2 14286
July 525.46 16289.3
August 458.88 14225.4
September 387.56 11626.7
October 281.26 8718.91
November 156.59 4697.71
December 116.45 3609.85
Total yearly 122146

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.72% angle of incidence loss and -2.49% temperature and irradiance loss. This totals to about -14.63%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Red LakeGoose Cove EastSavage Cove - Sandy CoveMoosoneePhilipsburgBarfordSherringtonL'AcadieSawyervilleSaint-Jean-Baptiste-de-RouvilleCarillonSainte-Julie-de-Verch�resSaint-CanutSaint-GerardPoltimoreSaint-Eug�ne-de-GranthamNew GlasgowSaint-Calixte-de-KilkennySaint-Gerard-d'YamaskaVianneyNotre-Dame-de-PierrevilleLac-MarsanLac-ChaudHervey-JonctionNotre-Dame-des-AngesMurdochville