Solar Calculator Canada

Solar Power Calculator for Carnduff, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Carnduff
  • GPS Coordinates: 49.174925, -101.7973306
  • Elevation: 529 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Carnduff: 43o
  • Average yearly irradiance: 1622.63 kWh/m2
  • Average yearly power output: 138166 kWh
Sun Path Carnduff

Average yearly irradiance delivered by the Sun in Carnduff is 1622.63/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 138166 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.43 75.37
February 3.14 87.94
March 3.95 122.31
April 5.54 166.21
May 5.63 174.63
June 5.83 174.86
July 6.53 202.42
August 6.07 188.06
September 5.35 160.44
October 3.99 123.64
November 2.76 82.95
December 2.06 63.81
Total yearly 1622.63

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 232.75 7215.21
February 297.23 8322.34
March 354.2 10980.1
April 476.72 14301.5
May 469.2 14545.3
June 471.46 14143.7
July 521.04 16152.3
August 486.8 15090.9
September 440.2 13206
October 344.42 10676.9
November 250.2 7506.11
December 194.39 6026.24
Total yearly 138166

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Carnduff solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 147.05 4558.62
February 215.07 6021.95
March 301.39 9343.12
April 458.04 13741.2
May 495.8 15369.7
June 519.24 15577.2
July 562.32 17431.8
August 485.46 15049.2
September 389.09 11672.8
October 266.94 8275.01
November 169.02 5070.51
December 117.28 3635.71
Total yearly 125747

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 166.14 5150.22
February 234.23 6558.52
March 315.67 9785.77
April 467.66 14029.8
May 496.89 15403.6
June 516.29 15488.8
July 561.91 17419.2
August 492.11 15255.5
September 404.32 12129.5
October 285.64 8854.94
November 187.37 5621.11
December 134.28 4162.69
Total yearly 129860

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 183.56 5690.38
February 251.43 7040.13
March 327.87 10163.8
April 474.6 14237.9
May 495.6 15363.7
June 511.45 15343.4
July 558.61 17316.8
August 496 15376.1
September 416.92 12507.7
October 302.25 9369.9
November 204.04 6121.21
December 149.87 4645.94
Total yearly 133177

Carnduff Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 199.29 6177.97
February 266.64 7465.93
March 337.94 10476.2
April 478.83 14364.8
May 491.6 15239.5
June 503.64 15109.2
July 552.13 17116
August 497.13 15411
September 426.91 12807.2
October 316.72 9818.3
November 218.99 6569.7
December 164 5084.08
Total yearly 135640

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.66% angle of incidence loss and -2.81% temperature and irradiance loss. This totals to about -14.85%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

RadissonMcAdamSouth RiverMintoNeguacNakuspPort AliceAshcroftWinnipegosisValemountVillage of Daajing GiidsMcBrideMassetFraser LakeBurns Lakenear TeslinMayoWindsorLondonSaint JohnMontrealDrummondvilleMonctonSault Ste. MarieBathurstMurdochville