Solar Calculator Canada

Solar Power Calculator for Eastend, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Eastend
  • GPS Coordinates: 49.5163028, -108.8198083
  • Elevation: 913 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Eastend: 42o
  • Average yearly irradiance: 1637.45 kWh/m2
  • Average yearly power output: 139101 kWh
Sun Path Eastend

Average yearly irradiance delivered by the Sun in Eastend is 1637.45/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 139101 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.16 67.01
February 3.15 88.27
March 4.01 124.39
April 5.49 164.59
May 5.82 180.41
June 5.98 179.48
July 6.77 209.98
August 6.38 197.67
September 5.33 159.96
October 4.2 130.05
November 2.66 79.93
December 1.8 55.72
Total yearly 1637.45

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 202.23 6269.02
February 290.81 8142.71
March 357.11 11070.3
April 474.01 14220.3
May 488.79 15152.6
June 488.2 14646
July 541.59 16789.3
August 512.39 15884
September 441.37 13241.2
October 363.48 11267.8
November 240.2 7205.91
December 168.13 5211.96
Total yearly 139101

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Eastend solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 130.35 4040.96
February 213.53 5978.75
March 305.79 9479.63
April 454.21 13626.3
May 510.19 15815.9
June 532.76 15982.8
July 577.83 17912.8
August 505.48 15670
September 389.78 11693.4
October 281.68 8732.19
November 163.27 4898.02
December 104.06 3225.79
Total yearly 127057

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 147.16 4561.84
February 232.28 6503.91
March 319.95 9918.32
April 463.54 13906.2
May 511.49 15856.2
June 529.46 15883.9
July 576.98 17886.5
August 513.08 15905.6
September 405.19 12155.8
October 302.1 9365.2
November 181.32 5439.51
December 118.76 3681.58
Total yearly 131065

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 162.52 5038.06
February 249.15 6976.08
March 332.03 10292.9
April 470.27 14108
May 510.2 15816.2
June 523.92 15717.8
July 573.4 17775.4
August 517.81 16052.1
September 418.01 12540.4
October 320.27 9928.43
November 197.76 5932.73
December 132.22 4098.73
Total yearly 134277

Eastend Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 176.4 5468.36
February 264.08 7394.17
March 342.01 10602.2
April 474.36 14230.8
May 506.19 15692
June 516.11 15483.4
July 567.35 17587.8
August 519.68 16110
September 428.16 12844.8
October 336.14 10420.3
November 212.54 6376.22
December 144.4 4476.42
Total yearly 136686

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.7% angle of incidence loss and -3% temperature and irradiance loss. This totals to about -15.05%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Val-d'OrThunder BaySaguenayRimouskiTimminsGasp�Corner BrookEstevanVancouverCranbrookLethbridgeBrandonKelownaChibougamauSept-IlesSwift CurrentKamloopsCalgaryDauphinYorktonWilliams LakeSaskatoonRed DeerLloydminsterLloydminsterMurdochville