Solar Calculator Canada

Solar Power Calculator for Fleming, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Fleming
  • GPS Coordinates: 50.074729, -101.513095
  • Elevation: 547 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Fleming: 43o
  • Average yearly irradiance: 1593 kWh/m2
  • Average yearly power output: 136242 kWh
Sun Path Fleming

Average yearly irradiance delivered by the Sun in Fleming is 1593/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 136242 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.32 71.82
February 3.3 92.37
March 3.84 118.9
April 5.56 166.85
May 5.69 176.31
June 5.74 172.18
July 6.4 198.52
August 5.87 181.84
September 5.2 155.87
October 3.92 121.4
November 2.53 75.76
December 1.97 61.19
Total yearly 1593

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 223.02 6913.54
February 313.7 8783.48
March 346.09 10728.7
April 479.74 14392.2
May 475.24 14732.5
June 466.07 13982
July 513.22 15909.8
August 472.97 14662
September 430.52 12915.6
October 339.93 10537.8
November 229.44 6883.11
December 187.15 5801.7
Total yearly 136242

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Fleming solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 139.8 4333.8
February 224.31 6280.66
March 292.55 9069.13
April 458.43 13753
May 499.15 15473.5
June 510.59 15317.6
July 550.18 17055.6
August 470.6 14588.5
September 379.33 11379.9
October 261.39 8103.16
November 153.67 4610.15
December 112.5 3487.37
Total yearly 123452

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 158.45 4911.95
February 245.19 6865.36
March 306.92 9514.55
April 468.52 14055.5
May 500.58 15517.9
June 507.87 15236
July 550.09 17052.9
August 477.1 14790.2
September 394.41 11832.3
October 280.35 8690.84
November 170.86 5125.87
December 129.09 4001.72
Total yearly 127595

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 175.49 5440.07
February 263.97 7391.15
March 319.23 9896.27
April 475.89 14276.7
May 499.7 15490.6
June 503.06 15091.7
July 547.33 16967.1
August 480.94 14909.1
September 406.97 12209.2
October 297.22 9213.91
November 186.5 5595.15
December 144.3 4473.27
Total yearly 130954

Fleming Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 190.87 5917.11
February 280.61 7857.17
March 329.46 10213.3
April 480.57 14417
May 496.03 15377.1
June 495.94 14878.1
July 541.43 16784.3
August 482.14 14946.3
September 416.95 12508.5
October 311.96 9670.77
November 200.56 6016.74
December 158.09 4900.77
Total yearly 133487

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.69% angle of incidence loss and -2.35% temperature and irradiance loss. This totals to about -14.47%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Saint-CharlesSainte-GermaineBridgevilleBarachoisVillemontelSaint-Georges-de-MalbaieSainte-RoseSaint-Nazaire-de-BerryGuyenneNotre-Dame-du-RosaireLanguedocSaint-Marc-de-LatourCap-des-RosiersSainte-�lisabeth-de-ProulxPetite-Rivi�re-au-RenardCap-SeizePetit-CapSaint-Maurice-de-l'�choueriePointe-JauneL'Anse-�-ValleauLes BuissonsPort-MenierRivi�re-Sainte-Marguerite-en-BasKegaskaSheldrakeMurdochville