Solar Calculator Canada

Solar Power Calculator for Gull Lake, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Gull Lake
  • GPS Coordinates: 50.0969139, -108.4847525
  • Elevation: 791 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Gull Lake: 42o
  • Average yearly irradiance: 1580.61 kWh/m2
  • Average yearly power output: 133914 kWh
Sun Path Gull Lake

Average yearly irradiance delivered by the Sun in Gull Lake is 1580.61/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 133914 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.08 64.41
February 3.02 84.56
March 4.03 124.98
April 5.44 163.18
May 5.65 175.21
June 5.72 171.69
July 6.65 206.16
August 6.03 186.99
September 5.12 153.74
October 3.97 123.1
November 2.39 71.67
December 1.77 54.94
Total yearly 1580.61

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 193.77 6006.97
February 277.65 7774.24
March 357.58 11085
April 468.78 14063.5
May 472.53 14648.4
June 464.89 13946.7
July 531.13 16465.1
August 484.1 15007
September 423.55 12706.4
October 343.31 10642.7
November 214.38 6431.49
December 165.68 5136.12
Total yearly 133914

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Gull Lake solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 124.19 3849.89
February 203.06 5685.81
March 304.36 9435.02
April 447.05 13411.4
May 492.59 15270.3
June 506.22 15186.7
July 564.66 17504.4
August 477.37 14798.4
September 373.24 11197.1
October 264.93 8212.86
November 145.61 4368.26
December 100.39 3112.21
Total yearly 122032

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 140.28 4348.62
February 221.1 6190.69
March 318.81 9883.14
April 456.65 13699.5
May 494.06 15315.9
June 503.37 15101
July 564.36 17495.1
August 484.52 15020
September 388.08 11642.3
October 284.24 8811.46
November 161.61 4848.35
December 115.25 3572.64
Total yearly 125929

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 154.99 4804.79
February 237.31 6644.7
March 331.19 10267
April 463.69 13910.5
May 493.04 15284.2
June 498.4 14951.9
July 561.42 17403.9
August 488.97 15158
September 400.44 12013.3
October 301.44 9344.64
November 176.19 5285.73
December 128.87 3994.86
Total yearly 129064

Gull Lake Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 168.3 5217.19
February 251.67 7046.83
March 341.46 10585.3
April 468.12 14043.5
May 489.41 15171.8
June 491.32 14739.7
July 556.01 17236.3
August 490.73 15212.6
September 410.3 12309.1
October 316.48 9810.8
November 189.3 5679.07
December 141.22 4377.88
Total yearly 131430

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.72% angle of incidence loss and -3.24% temperature and irradiance loss. This totals to about -15.28%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Val-d'OrThunder BaySaguenayRimouskiTimminsGasp�Corner BrookEstevanVancouverCranbrookLethbridgeBrandonKelownaChibougamauSept-IlesSwift CurrentKamloopsCalgaryDauphinYorktonWilliams LakeSaskatoonRed DeerLloydminsterLloydminsterMurdochville