Solar Calculator Canada

Solar Power Calculator for Shaunavon, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Shaunavon
  • GPS Coordinates: 49.6503486, -108.4159917
  • Elevation: 916 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Shaunavon: 42o
  • Average yearly irradiance: 1592.09 kWh/m2
  • Average yearly power output: 135161 kWh
Sun Path Shaunavon

Average yearly irradiance delivered by the Sun in Shaunavon is 1592.09/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 135161 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.13 66.07
February 2.91 81.56
March 3.88 120.38
April 5.38 161.45
May 5.68 175.99
June 5.8 173.98
July 6.72 208.41
August 6.23 193.19
September 5.21 156.26
October 4.05 125.46
November 2.5 75.03
December 1.75 54.3
Total yearly 1592.09

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 199.69 6190.38
February 268.41 7515.37
March 345.46 10709.2
April 465.05 13951.4
May 476.29 14765.1
June 472.46 14173.7
July 537.62 16666.4
August 501.04 15532.1
September 431.7 12951.1
October 350.5 10865.6
November 225.35 6760.39
December 163.89 5080.67
Total yearly 135161

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Shaunavon solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 128.63 3987.67
February 197.48 5529.55
March 295.12 9148.83
April 445.99 13379.8
May 497.26 15415
June 515.06 15451.9
July 572.62 17751.2
August 494.14 15318.2
September 381.68 11450.4
October 272.37 8443.62
November 153.72 4611.49
December 100.91 3128.25
Total yearly 123616

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 145.31 4504.67
February 214.78 6013.94
March 308.98 9578.25
April 455.03 13650.8
May 498.48 15453
June 511.79 15353.7
July 571.9 17728.9
August 501.55 15548.1
September 396.59 11897.7
October 291.89 9048.74
November 170.58 5117.31
December 115.42 3578.12
Total yearly 127473

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 160.56 4977.48
February 230.33 6449.37
March 320.81 9945.25
April 461.52 13845.6
May 497.16 15411.9
June 506.46 15193.8
July 568.55 17625.2
August 506.13 15690.2
September 408.97 12269.2
October 309.26 9586.91
November 185.94 5578.21
December 128.72 3990.31
Total yearly 130563

Shaunavon Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 174.35 5404.88
February 244.1 6834.82
March 330.6 10248.8
April 465.43 13963
May 493.22 15289.7
June 498.79 14963.8
July 562.57 17439.6
August 507.91 15745.1
September 418.8 12564
October 324.4 10056.5
November 199.76 5992.74
December 140.77 4363.9
Total yearly 132867

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.72% angle of incidence loss and -3.03% temperature and irradiance loss. This totals to about -15.1%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

Val-d'OrThunder BaySaguenayRimouskiTimminsGasp�Corner BrookEstevanVancouverCranbrookLethbridgeBrandonKelownaChibougamauSept-IlesSwift CurrentKamloopsCalgaryDauphinYorktonWilliams LakeSaskatoonRed DeerLloydminsterLloydminsterMurdochville