Solar Calculator Canada

Solar Power Calculator for Simpson, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Simpson
  • GPS Coordinates: 51.4525983, -105.4450278
  • Elevation: 519 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Simpson: 43o
  • Average yearly irradiance: 1496.91 kWh/m2
  • Average yearly power output: 127550 kWh
Sun Path Simpson

Average yearly irradiance delivered by the Sun in Simpson is 1496.91/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 127550 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.82 56.41
February 2.7 75.67
March 3.54 109.75
April 5.23 156.89
May 5.82 180.32
June 5.61 168.45
July 6.35 196.82
August 5.78 179.14
September 4.92 147.54
October 3.57 110.6
November 2.13 63.86
December 1.66 51.47
Total yearly 1496.91

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 174.82 5419.54
February 256.48 7181.36
March 319.31 9898.59
April 451.25 13537.6
May 485.97 15065.1
June 455.87 13676
July 509.2 15785.3
August 466.13 14450.2
September 408.38 12251.4
October 309.18 9584.73
November 192.88 5786.54
December 158.52 4913.98
Total yearly 127550

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Simpson solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 106.99 3316.64
February 180.59 5056.39
March 266.5 8261.63
April 426.59 12797.8
May 504.08 15626.4
June 493.73 14811.9
July 541.59 16789.3
August 459.53 14245.3
September 356.52 10695.7
October 235.61 7303.78
November 126.55 3796.48
December 91.29 2830.1
Total yearly 115531

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 122.17 3787.29
February 198.48 5557.48
March 280.73 8702.57
April 436.58 13097.5
May 506.8 15710.7
June 492.47 14774.1
July 542.28 16810.8
August 466.71 14468
September 371.35 11140.4
October 253.36 7854.1
November 141.51 4245.18
December 106.15 3290.65
Total yearly 119439

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 136.08 4218.63
February 214.64 6010.02
March 293 9083.05
April 444.04 13321.3
May 506.49 15701.2
June 488.79 14663.8
July 540.35 16750.8
August 471.21 14607.7
September 383.77 11513.1
October 269.21 8345.64
November 155.16 4654.68
December 119.82 3714.48
Total yearly 122584

Simpson Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 148.7 4609.62
February 229.04 6413.16
March 303.3 9402.28
April 448.96 13468.7
May 503.49 15608.2
June 482.3 14469.1
July 535.13 16589
August 473.09 14665.7
September 393.75 11812.6
October 283.12 8776.86
November 167.46 5023.77
December 132.27 4100.26
Total yearly 124939

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.72% angle of incidence loss and -2.68% temperature and irradiance loss. This totals to about -14.79%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

AlbertvilleMeath ParkWhite FoxLoveSmeatonPaddockwoodMarwayneDebdenParadise HillChristopher LakeLeovilleMyrnamAlberta BeachPort ClementsChipmanOnowayAndrewSangudoMakwaLoon LakeWaskatenauVilnaClydeGlendonPiercelandMurdochville