Solar Calculator Canada

Solar Power Calculator for Theodore, Saskatchewan, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Theodore
  • GPS Coordinates: 51.424657, -102.922556
  • Elevation: 524 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Theodore: 43o
  • Average yearly irradiance: 1528.79 kWh/m2
  • Average yearly power output: 130619 kWh
Sun Path Theodore

Average yearly irradiance delivered by the Sun in Theodore is 1528.79/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 130619 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.99 61.56
February 2.99 83.82
March 3.71 115.06
April 5.41 162.36
May 5.75 178.31
June 5.65 169.52
July 6.23 193.16
August 5.79 179.6
September 4.98 149.47
October 3.76 116.47
November 2.21 66.22
December 1.72 53.24
Total yearly 1528.79

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 191.67 5941.62
February 284.51 7966.19
March 334.43 10367.3
April 466.86 14005.9
May 480.23 14887.3
June 458.98 13769.5
July 500.02 15500.8
August 468.12 14511.9
September 414.6 12437.9
October 326.74 10128.9
November 201.15 6034.51
December 163.45 5067.09
Total yearly 130619

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Theodore solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 117.62 3646.26
February 199.75 5592.93
March 278.35 8629
April 443.95 13318.6
May 502.76 15585.7
June 499.57 14987
July 533.04 16524.1
August 462.96 14351.9
September 363.01 10890.2
October 246.73 7648.59
November 131.27 3938.1
December 95.88 2972.36
Total yearly 118085

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 133.9 4150.86
February 219.09 6134.44
March 292.83 9077.66
April 454.28 13628.5
May 504.97 15654.2
June 497.99 14939.8
July 533.88 16550.3
August 469.96 14568.8
September 377.93 11337.8
October 265.61 8233.99
November 146.84 4405.08
December 110.66 3430.33
Total yearly 122112

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 148.78 4612.11
February 236.52 6622.43
March 305.29 9463.85
April 461.98 13859.5
May 504.74 15646.9
June 494.29 14828.6
July 531.72 16483.4
August 474.33 14704.4
September 390.41 11712.4
October 282.48 8756.84
November 161.04 4831.16
December 124.21 3850.61
Total yearly 125372

Theodore Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 162.23 5029.24
February 252.01 7056.16
March 315.7 9786.85
April 467.03 14010.8
May 501.66 15551.4
June 487.71 14631.2
July 526.52 16322.2
August 476.07 14758.2
September 400.43 12012.9
October 297.28 9215.61
November 173.83 5215.04
December 136.52 4232.14
Total yearly 127822

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.7% angle of incidence loss and -2.44% temperature and irradiance loss. This totals to about -14.56%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

AlbertvilleMeath ParkWhite FoxLoveSmeatonPaddockwoodMarwayneDebdenParadise HillChristopher LakeLeovilleMyrnamAlberta BeachPort ClementsChipmanOnowayAndrewSangudoMakwaLoon LakeWaskatenauVilnaClydeGlendonPiercelandMurdochville