Solar Calculator Canada

Solar Power Calculator for Airdrie, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Airdrie
  • GPS Coordinates: 51.2922222, -114.0141667
  • Elevation: 1085 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technoloty: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Airdrie: 43o
  • Average yearly irradiance: 1533.91 kWh/m2
  • Average yearly power output: 128490 kWh
Sun Path Airdrie

Average yearly irradiance delivered by the Sun in Airdrie is 1533.91/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 128490 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.06 63.98
February 2.87 80.32
March 3.81 118.19
April 5.01 150.21
May 5.65 175.16
June 5.57 167.15
July 6.34 196.58
August 5.83 180.69
September 5.03 150.82
October 3.73 115.61
November 2.54 76.27
December 1.9 58.92
Total yearly 1533.91

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 187.53 5813.3
February 256.01 7168.36
March 331.15 10265.8
April 425.44 12763.2
May 466.18 14451.6
June 450.26 13507.7
July 503.46 15607.3
August 465.73 14437.6
September 412.23 12367
October 318.55 9875.02
November 227.6 6828.13
December 174.35 5405
Total yearly 128490

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) fals between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Airdrie solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 117.62 3646.32
February 185.73 5200.34
March 279.9 8676.82
April 407.61 12228.2
May 485.1 15038.1
June 488.27 14648
July 534.75 16577.1
August 458.36 14209.1
September 361.38 10841.5
October 243.85 7559.39
November 148.64 4459.28
December 102.77 3185.92
Total yearly 116270

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 133.37 4134.35
February 202.21 5661.88
March 293.57 9100.74
April 416.03 12480.9
May 486.67 15086.9
June 485.98 14579.3
July 534.74 16576.8
August 465.52 14431.1
September 376.1 11283.1
October 261.9 8118.75
November 166.46 4993.9
December 118.68 3679.03
Total yearly 120127

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 147.74 4579.94
February 217 6076.11
March 305.32 9465.05
April 422.22 12666.6
May 486 15066
June 481.51 14445.3
July 532.35 16503
August 470.16 14575
September 388.41 11652.2
October 277.97 8617.06
November 182.7 5481.1
December 133.27 4131.23
Total yearly 123259

Airdrie Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 160.72 4982.26
February 230.09 6442.47
March 315.13 9768.96
April 426.03 12781
May 483.34 14983.6
June 475.12 14253.7
July 527.74 16360
August 472.15 14636.6
September 398.26 11947.9
October 292.04 9053.14
November 197.33 5919.78
December 146.5 4541.5
Total yearly 125671

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.71% angle of incidence loss and -4.33% temperature and irradiance loss. This totals to about -16.23%%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels loose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: