Solar Calculator Canada

Solar Power Calculator for Coaldale, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Coaldale
  • GPS Coordinates: 49.7277777, -112.6186111
  • Elevation: 864 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Coaldale: 42o
  • Average yearly irradiance: 1667.63 kWh/m2
  • Average yearly power output: 138700 kWh
Sun Path Coaldale

Average yearly irradiance delivered by the Sun in Coaldale is 1667.63/kWh/m2 at the optimal panel slope of 42o. After taking all losses into account, you can expect about 138700 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 42o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.31 71.64
February 3.16 88.56
March 4.27 132.44
April 5.46 163.81
May 5.92 183.48
June 6.05 181.58
July 6.93 214.94
August 6.37 197.53
September 5.34 160.12
October 4.04 125.33
November 2.76 82.84
December 2.11 65.36
Total yearly 1667.63

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 208.61 6466.96
February 281.23 7874.31
March 370.37 11481.6
April 461.36 13840.8
May 485.43 15048.3
June 485.56 14566.9
July 543.84 16859
August 502.38 15573.9
September 433.45 13003.5
October 344.22 10670.9
November 245.31 7359.38
December 192.08 5954.56
Total yearly 138700

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Coaldale solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 134.47 4168.61
February 208.18 5829.18
March 315.88 9792.41
April 442.23 13267
May 507.42 15729.9
June 528.03 15841
July 579.81 17974.2
August 496.09 15378.7
September 382.93 11488
October 267.08 8279.43
November 164.86 4945.81
December 117.31 3636.49
Total yearly 126331

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 151.49 4696.29
February 225.76 6321.38
March 330.77 10253.9
April 451.46 13543.9
May 508.64 15768
June 525.03 15750.8
July 579.15 17953.6
August 503.51 15608.8
September 397.95 11938.6
October 286.13 8869.96
November 183.49 5504.76
December 134.29 4162.87
Total yearly 130373

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 167.04 5178.12
February 241.53 6762.87
March 343.52 10649
April 458.18 13745.4
May 507.53 15733.4
June 519.63 15588.9
July 575.76 17848.4
August 508.25 15755.8
September 410.42 12312.5
October 303.06 9394.92
November 200.45 6013.5
December 149.87 4646.1
Total yearly 133629

Coaldale Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 181.06 5612.95
February 255.46 7152.76
March 354.08 10976.6
April 462.19 13865.6
May 504.32 15634
June 512.02 15360.5
July 570.09 17672.7
August 510.02 15810.5
September 420.29 12608.6
October 317.83 9852.87
November 215.69 6470.75
December 164.02 5084.57
Total yearly 136103

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.68% angle of incidence loss and -5.04% temperature and irradiance loss. This totals to about -16.83%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.