Solar Calculator Canada

Solar Power Calculator for Bowden, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Bowden
  • GPS Coordinates: 51.9322222, -114.0347222
  • Elevation: 993 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Bowden: 43o
  • Average yearly irradiance: 1493.07 kWh/m2
  • Average yearly power output: 125425 kWh
Sun Path Bowden

Average yearly irradiance delivered by the Sun in Bowden is 1493.07/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 125425 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.86 57.51
February 2.57 72.03
March 3.46 107.16
April 5.02 150.74
May 5.83 180.82
June 5.75 172.5
July 6.32 195.77
August 5.77 178.97
September 4.9 147.13
October 3.6 111.71
November 2.36 70.82
December 1.54 47.89
Total yearly 1493.07

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 169.97 5268.92
February 231.62 6485.36
March 301.05 9332.54
April 428.92 12867.6
May 483.9 15000.9
June 466.5 13995.1
July 503.84 15619.2
August 463.74 14375.8
September 404.35 12130.5
October 309.12 9582.63
November 212.05 6361.47
December 142.09 4404.64
Total yearly 125425

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Bowden solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 105.05 3256.61
February 165.28 4627.8
March 252.09 7814.83
April 408.22 12246.6
May 500.62 15519.2
June 502.56 15076.9
July 531.99 16491.6
August 453.97 14073
September 353.67 10610.2
October 234.96 7283.65
November 137.25 4117.37
December 83.99 2603.8
Total yearly 113722

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 119.7 3710.6
February 180.89 5064.97
March 265.12 8218.69
April 417.28 12518.5
May 502.91 15590.1
June 500.87 15026.1
July 532.45 16506
August 461.5 14306.4
September 368.3 11049.1
October 252.83 7837.6
November 154.19 4625.69
December 96.98 3006.5
Total yearly 117460

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 133.09 4125.7
February 194.93 5458.11
March 276.35 8566.78
April 424.06 12721.9
May 502.79 15586.4
June 496.86 14905.7
July 530.47 16444.6
August 466.52 14462.2
September 380.57 11417
October 268.77 8332.01
November 169.66 5089.68
December 108.89 3375.47
Total yearly 120486

Bowden Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 145.2 4501.11
February 207.39 5806.79
March 285.76 8858.51
April 428.43 12852.9
May 500.5 15515.4
June 490.65 14719.5
July 526.34 16316.4
August 468.91 14536.1
September 390.43 11713
October 282.76 8765.66
November 183.61 5508.16
December 119.68 3710.06
Total yearly 122804

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.69% angle of incidence loss and -4.08% temperature and irradiance loss. This totals to about -16%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

DouglastownDidymeRivi�re-au-RenardBeaucantonVilleboisVal-ParadisMont-LouisMadeleine-CentreLa RomaineMinganHarrington HarbourMutton BayNewburyOil SpringsFreeportWeymouthChesterWestportGrand MananMerrickville-WolfordLawrencetownGreenwoodKingstonAylesfordBlacks HarbourMurdochville