Solar Calculator Canada

Solar Power Calculator for Delia, Alberta, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Delia
  • GPS Coordinates: 51.6305556, -112.3738889
  • Elevation: 906 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Delia: 43o
  • Average yearly irradiance: 1501.64 kWh/m2
  • Average yearly power output: 126929 kWh
Sun Path Delia

Average yearly irradiance delivered by the Sun in Delia is 1501.64/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 126929 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.8 55.87
February 2.67 74.79
March 3.63 112.52
April 5.17 155.02
May 5.79 179.6
June 5.69 170.81
July 6.47 200.68
August 5.81 180.21
September 4.9 146.99
October 3.59 111.18
November 2.22 66.47
December 1.53 47.52
Total yearly 1501.64

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 167.37 5188.32
February 245.2 6865.66
March 320.55 9937.11
April 444.41 13332.2
May 483 14972.9
June 463.01 13890.2
July 517.13 16031.2
August 468.12 14511.6
September 405.64 12169.2
October 309.53 9595.29
November 200 6000
December 143.07 4435.32
Total yearly 126929

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Delia solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 104.49 3239.25
February 175.6 4916.93
March 268.43 8321.4
April 422.68 12680.4
May 500.63 15519.4
June 499.35 14980.5
July 546.34 16936.6
August 459.04 14230.3
September 355.32 10659.6
October 236.85 7342.33
November 132.09 3962.73
December 85.45 2648.81
Total yearly 115438

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 118.77 3681.75
February 192.05 5377.52
March 282.33 8752.1
April 432.19 12965.8
May 502.57 15579.5
June 497.36 14920.8
July 546.7 16947.7
August 466.47 14460.7
September 369.84 11095.3
October 254.49 7889.24
November 147.65 4429.64
December 98.42 3051.06
Total yearly 119151

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 131.84 4086.96
February 206.87 5792.36
March 294.31 9123.69
April 439.34 13180.3
May 502.13 15566.2
June 493.07 14792.2
July 544.37 16875.4
August 471.45 14615.1
September 382.01 11460.2
October 270.24 8377.36
November 161.85 4855.54
December 110.32 3419.84
Total yearly 122145

Delia Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 143.67 4453.85
February 220.03 6160.74
March 304.37 9435.32
April 443.92 13317.7
May 499.5 15484.6
June 486.62 14598.5
July 539.76 16732.6
August 473.78 14687.2
September 391.77 11753
October 284.04 8805.22
November 174.64 5239.26
December 121.11 3754.43
Total yearly 124422

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.74% angle of incidence loss and -3.44% temperature and irradiance loss. This totals to about -15.47%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

DorintoshGoodsoilBoyleTelkwaGranisleHazeltonHytheKinusoPouce CoupeDonnellyGirouxvilleRycroftNampaBerwynHines CreekMerrittLourdes-de-Blanc-SablonChatham-KentSt. ThomasSarniaWellandNiagara FallsWoodstockBrantfordSt. CatharinesMurdochville