Solar Calculator Canada

Solar Power Calculator for Telkwa, British Columbia, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Telkwa
  • GPS Coordinates: 54.696667, -127.050833
  • Elevation: 511 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Telkwa: 41o
  • Average yearly irradiance: 1262.41 kWh/m2
  • Average yearly power output: 106528 kWh
Sun Path Telkwa

Average yearly irradiance delivered by the Sun in Telkwa is 1262.41/kWh/m2 at the optimal panel slope of 41o. After taking all losses into account, you can expect about 106528 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 41o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.21 37.44
February 2.36 65.98
March 3.27 101.51
April 4.66 139.72
May 5.24 162.38
June 5.45 163.4
July 5.5 170.51
August 5.14 159.49
September 3.84 115.1
October 2.28 70.71
November 1.43 42.81
December 1.08 33.37
Total yearly 1262.41

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 109.07 3381.12
February 211.55 5923.27
March 289.63 8978.39
April 404.04 12121.3
May 439.03 13609.8
June 445.96 13378.8
July 443.23 13740.1
August 416.41 12908.8
September 318.4 9551.98
October 195.84 6071.18
November 126.63 3798.85
December 98.86 3064.57
Total yearly 106528

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Telkwa solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 69.55 2156.04
February 154.23 4318.48
March 247.21 7663.56
April 382.67 11480.2
May 448.66 13908.5
June 471.67 14150
July 461.86 14317.8
August 406.63 12605.5
September 282.26 8467.7
October 155.84 4830.9
November 85.09 2552.55
December 57.82 1792.43
Total yearly 98243.5

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 78.92 2446.41
February 168.34 4713.41
March 258.55 8015.17
April 390.96 11728.7
May 450.71 13972
June 470.55 14116.4
July 462.34 14332.7
August 412.94 12801.3
September 292.86 8785.79
October 166.14 5150.2
November 95.09 2852.64
December 67.36 2088.27
Total yearly 101003

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 87.47 2711.67
February 181.02 5068.43
March 268.29 8316.92
April 397.23 11916.8
May 450.68 13971.2
June 467.32 14019.7
July 460.69 14281.4
August 417.18 12932.7
September 301.69 9050.81
October 175.29 5433.95
November 104.21 3126.24
December 76.15 2360.8
Total yearly 103191

Telkwa Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 95.2 2951.23
February 192.25 5383.11
March 276.39 8567.95
April 401.38 12041.3
May 448.72 13910.3
June 462.1 13862.9
July 456.99 14166.7
August 419.46 13003.2
September 308.73 9261.98
October 183.27 5681.22
November 112.42 3372.63
December 84.16 2608.99
Total yearly 104811

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.97% angle of incidence loss and -3.37% temperature and irradiance loss. This totals to about -15.62%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: