Solar Calculator Canada

Solar Power Calculator for Chatham-Kent, Ontario, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Chatham-Kent
  • GPS Coordinates: 42.43396, -82.12876
  • Elevation: 181 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Chatham-Kent: 34o
  • Average yearly irradiance: 1586.28 kWh/m2
  • Average yearly power output: 132495 kWh
Sun Path Chatham-Kent

Average yearly irradiance delivered by the Sun in Chatham-Kent is 1586.28/kWh/m2 at the optimal panel slope of 34o. After taking all losses into account, you can expect about 132495 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 34o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.09 64.78
February 2.88 80.74
March 4.32 133.88
April 5.27 158.13
May 5.85 181.23
June 6.08 182.47
July 6.18 191.51
August 5.9 182.82
September 5.01 150.19
October 3.85 119.2
November 2.81 84.43
December 1.84 56.9
Total yearly 1586.28

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 190.86 5916.79
February 263.47 7377.18
March 380.93 11809
April 448.65 13459.6
May 479.97 14879.2
June 488.03 14640.9
July 488.86 15154.7
August 469.06 14540.9
September 406.85 12205.5
October 324.79 10068.5
November 245.64 7369.08
December 163.67 5073.76
Total yearly 132495

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Chatham-Kent solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 150.7 4671.64
February 222.75 6236.96
March 349.51 10834.9
April 442.29 13268.8
May 499.68 15490.1
June 520.64 15619.3
July 517.15 16031.7
August 473.13 14667.1
September 382.56 11476.9
October 282.17 8747.13
November 196.61 5898.42
December 126.42 3918.95
Total yearly 126862

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 163 5052.98
February 235.67 6598.65
March 360.79 11184.6
April 447.43 13423
May 497.98 15437.4
June 515.24 15457.2
July 513.01 15903.5
August 475.84 14751.2
September 392.17 11765.2
October 296.01 9176.2
November 211.66 6349.89
December 137.77 4270.85
Total yearly 129371

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 174.04 5395.27
February 246.98 6915.57
March 369.95 11468.3
April 450.1 13503
May 493.97 15313.2
June 507.82 15234.6
July 506.82 15711.4
August 475.9 14753
September 399.49 11984.6
October 307.94 9546.09
November 225.14 6754.23
December 148.02 4588.7
Total yearly 131168

Chatham-Kent Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 183.79 5697.61
February 256.67 7186.75
March 376.93 11684.8
April 450.31 13509.4
May 487.43 15110.5
June 498.39 14951.8
July 498.25 15445.8
August 473.26 14671.1
September 404.46 12133.8
October 317.92 9855.41
November 237 7110.08
December 157.14 4871.49
Total yearly 132228

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.87% angle of incidence loss and -4.45% temperature and irradiance loss. This totals to about -16.47%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

SelkirkVernonMoose JawBrooksMelvilleRevelstokeAirdrieHumboldtLacombeNorth BattlefordFermontMelfortWetaskiwinQuesnelCamrosePrince AlbertLeducSpruce GroveSt. AlbertFort SaskatchewanMeadow LakeCold LakeTerraceScheffervilleDawson CreekMurdochville